Molded Case Circuit Breakers Industrial Circuit Breakers Quick Reference Guide 10-1200A Circuit Breakers Thermal Magnetic Trip

Section 6

Ratings do not apply to molded case switches. Maximum interruption ratings and voltages shown. A circuit breaker of the type given in the left-hand column may be applied at the given cir- cuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage.

TEYD, TEYH, TEYL

TEY and TEYF (UL/cUL File E-11592; TEYD/H/L (UL/cUL File E-11592)

UL Listed Interrupting Rating—kA

Maximum Voltage Rating

Vac

Vdc

Dimensions (in)

Approx. Ship Wt./Std. Pack

Circuit Breaker Type

Ampere Rating

No. Poles

ac

dc

120 120/

W D A

B

C

E

240 240 277 480/277 480 600 125 250 500 H

1

277

125 65

10 — —

1

14 14

— —

TEY 2,3

15-100

2

250

— 10 —

5 1/4

2

3 1/16 — — — —

480/277

65 14 14

3

— — —

3

15-60

1

277

125 65

18 18

— —

10 — —

1

TEYF 2,3

5 1/4

2

250

— 10 —

3 1/16 — — — —

2

15-125

480/277

65 18 18

3

— — —

3

15-70

1

277

— 65 65 — 25

— — — — — —

1

1 lb

TEYD

5 1/4

3 1/16 — — — —

2

2

2 lb

15-125

480/277 — — 65 65 — 25

— — — — —

3

3

2.7 lb

15-70

1

277

— 65 65 — 35

— — — — — —

1

1 lb

TEYH

5 1/4

3 1/16 — — — —

2

2

2 lb

15-125

480/277 — — 65 65 — 35

— — — — —

3

3

2.7 lb

15-70

1

277

125 100 100 — 65

— — — 15 — —

1

1 lb

TEYL

2

42 20 —

5 1/4

2

3 1/16 — — — —

2 lb

15-125

480/277 250

— 100 100 — 65

— —

3

42 35 —

3

2.7 lb

E150 (UL/cUL File E-11592)

1

120

125 10

5 — —

1 3/8

26 lb/24

TEB 2,3

10-100 4

2

250

10

— — — —

— 5 —

6 5/16

2 3/4

3 3/8 2 41/64 2 15/64

23/32

24 lb/12

240

3

10

— — —

4 1/8

11/16

28 lb/8

1 277, 347 5

125

— 14

— 10 — 10 — —

1 3/8

26 lb/24

10-100 4

TED 2,3

2

480

250

— —

— — 10 — 14 — 10 10 1

6 5/16

2 3/4

3 3/8 2 41/64 2 15/64

23/32

24 lb/12

18 — — 18

10-150 4

3 7

480, 600 500

4 1/8

11/16

28 lb/8

1 277, 347 5

— — — 10 6

— 65

15-30

125

— —

1 3/8

26 lb/24

10 6

15-100 20-100 110-150

65 65 42

2

480

250

24 lb/12

THED 2,3

— —

6 5/16

3 3/8 2 41/64 2 15/64

23/32

— — 25

4 1/8

11/16

10 10 1

3 7

18

600

500

28 lb/8

J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit)

2

250

— 20 —

16 lb/1

TJJ, TJK4

200-400

600

— — 42 — — 30 22

10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16

17 1/2 lb/1

3

500

— 20 20 1

2

250

— 20 —

18 lb/1

TJK6 250-600

600

— — 42 — — 30 22

10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16

3

500

— 20 20 1

20 lb/1

2

250

— 40 —

16 lb/1

THJK4 200-400

600

— — 65 — — 35 25

10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16

17 1/2 lb/1

3

500

— 40 20 1

2

250

— 40 —

18 lb/1

THJK6 250-600

600

— — 65 — — 35 25

10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16

3

500

— 40 20 1

20 lb/1

Mag-Break (UL Files E-11592, E-66390; Magnetic Trip Unit) 8

600 — — — 42 — — 30 22 — — — 10 1/8 8 1/4 3 13/16 3 13/16 3 13/16 1 3/8 1 3/16 16 lb/1 17 1/2 lb/1

TJC 400-600 3

1 UL listed with poles in series for 500 Vdc ungrounded battery applications . 2 UL listed as HACR (heating, air conditioning, and refrigeration). 3 15-50A UL listed as HID (high intensity discharge). 4 10 amp not UL listed, rated 5kA @ 120V, 240V and 480V

5 UL/cUL listed for 10kA @ 347 Vac (TED) and 18kA @ 347V (THED). Rated 10kA @ 480V but not UL listed. 6 UL listed 10kA, GE tested to 20kA. 7 TED, 3P, 600V, 15A breaker is obsolete. (TED136015WL & THED136015WL) 8 Per UL 489, interrupting capacities are not shown on product label.

Rev. 1/19 Data subject to change without notice