GE Products BuyLog Smart Catalog
Molded Case Circuit Breakers Industrial Circuit Breakers Quick Reference Guide 10-1200A Circuit Breakers Thermal Magnetic Trip
Section 6
Ratings do not apply to molded case switches. Maximum interruption ratings and voltages shown. A circuit breaker of the type given in the left-hand column may be applied at the given cir- cuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage.
TEYD, TEYH, TEYL
TEY and TEYF (UL/cUL File E-11592; TEYD/H/L (UL/cUL File E-11592)
UL Listed Interrupting Rating—kA
Maximum Voltage Rating
Vac
Vdc
Dimensions (in)
Approx. Ship Wt./Std. Pack
Circuit Breaker Type
Ampere Rating
No. Poles
ac
dc
120 120/
W D A
B
C
E
240 240 277 480/277 480 600 125 250 500 H
1
277
125 65
10 — —
1
14 14
— —
TEY 2,3
15-100
2
250
—
—
— 10 —
5 1/4
2
3 1/16 — — — —
—
480/277
—
65 14 14
—
3
—
— — —
3
15-60
1
277
125 65
18 18
— —
10 — —
1
TEYF 2,3
—
—
5 1/4
2
250
— 10 —
3 1/16 — — — —
—
2
15-125
480/277
—
65 18 18
—
3
—
— — —
3
15-70
1
277
— 65 65 — 25
— — — — — —
1
1 lb
TEYD
5 1/4
3 1/16 — — — —
2
2
2 lb
15-125
480/277 — — 65 65 — 25
— — — — —
3
3
2.7 lb
15-70
1
277
— 65 65 — 35
— — — — — —
1
1 lb
TEYH
5 1/4
3 1/16 — — — —
2
2
2 lb
15-125
480/277 — — 65 65 — 35
— — — — —
3
3
2.7 lb
15-70
1
277
125 100 100 — 65
— — — 15 — —
1
1 lb
TEYL
2
42 20 —
5 1/4
2
3 1/16 — — — —
2 lb
15-125
480/277 250
— 100 100 — 65
— —
3
42 35 —
3
2.7 lb
E150 (UL/cUL File E-11592)
1
120
125 10
—
5 — —
1 3/8
26 lb/24
—
TEB 2,3
10-100 4
2
250
—
10
— — — —
— 5 —
6 5/16
2 3/4
3 3/8 2 41/64 2 15/64
23/32
24 lb/12
240
—
3
—
10
— — —
4 1/8
11/16
28 lb/8
1 277, 347 5
125
— 14
— 10 — 10 — —
1 3/8
26 lb/24
10-100 4
—
TED 2,3
2
480
250
— —
— — 10 — 14 — 10 10 1
6 5/16
2 3/4
3 3/8 2 41/64 2 15/64
23/32
24 lb/12
18 — — 18
10-150 4
3 7
480, 600 500
4 1/8
11/16
28 lb/8
1 277, 347 5
— — — 10 6
— 65
15-30
125
— —
1 3/8
—
26 lb/24
10 6
15-100 20-100 110-150
65 65 42
—
—
2
480
250
24 lb/12
THED 2,3
— —
6 5/16
3 3/8 2 41/64 2 15/64
23/32
— — 25
4 1/8
11/16
—
10 10 1
3 7
18
600
500
28 lb/8
J600 (UL File E-11592; TJJ, Fixed Thermal Magnetic Trip Unit; TJK, THJK: Interchangeable Thermal Mag. Trip Unit)
2
250
— 20 —
16 lb/1
TJJ, TJK4
200-400
600
— — 42 — — 30 22
10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
17 1/2 lb/1
3
500
— 20 20 1
2
250
— 20 —
18 lb/1
TJK6 250-600
600
— — 42 — — 30 22
10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3
500
— 20 20 1
20 lb/1
2
250
— 40 —
16 lb/1
THJK4 200-400
600
— — 65 — — 35 25
10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
17 1/2 lb/1
3
500
— 40 20 1
2
250
— 40 —
18 lb/1
THJK6 250-600
600
— — 65 — — 35 25
10 1/8 8 1/4 3 13/16 3 15/16 3 13/16 1 3/8 1 3/16
3
500
— 40 20 1
20 lb/1
Mag-Break (UL Files E-11592, E-66390; Magnetic Trip Unit) 8
600 — — — 42 — — 30 22 — — — 10 1/8 8 1/4 3 13/16 3 13/16 3 13/16 1 3/8 1 3/16 16 lb/1 17 1/2 lb/1
TJC 400-600 3
1 UL listed with poles in series for 500 Vdc ungrounded battery applications . 2 UL listed as HACR (heating, air conditioning, and refrigeration). 3 15-50A UL listed as HID (high intensity discharge). 4 10 amp not UL listed, rated 5kA @ 120V, 240V and 480V
5 UL/cUL listed for 10kA @ 347 Vac (TED) and 18kA @ 347V (THED). Rated 10kA @ 480V but not UL listed. 6 UL listed 10kA, GE tested to 20kA. 7 TED, 3P, 600V, 15A breaker is obsolete. (TED136015WL & THED136015WL) 8 Per UL 489, interrupting capacities are not shown on product label.
Rev. 1/19 Data subject to change without notice
go.abb/industrial
GE Products BuyLog
6-7