GE Products BuyLog Smart Catalog

Molded Case Circuit Breakers Industrial Circuit Breakers Quick Reference Guide 15-600A Record Plus ™ Circuit Breakers

Section 6

The interruption ratings and voltages shown in the table are maximum ratings. A circuit breaker of the type given in the left-hand column may be applied at the given circuit voltage in any electrical distribution system where the available fault current at the load terminals of the breaker does not exceed the value in the table. That circuit breaker type may also be applied at intermediate values of circuit voltage provided the available fault current at the load terminals of the breaker does not exceed the value in the table for the higher value of voltage.

FG 600

Ratings FC 100 Amp Frame; Current Limiting (UL/cUL File No. E-11592)

Maximum UL Listed Interrupting Ratings - IEC Listed Interrupting Ratings, Approx. Circuit Voltage rms Symmetrical Amperes (in Thousands) Icu, Amperes (in Thousands) Ship Breaker Ampere No. Rating Vac Vdc Vac Vdc Dimensions in. (mm.) Wt./Std. Type Rating Poles AC DC 240 480 600/347 250 (2p) 500 (3p) 220-240 400-415 500 250 (2p) 500 (3p) H W D Pack FCS 15-100 2, 3 600 500 42 25 18 22 30 36 22 14 22 30 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1 FCV 15-100 2, 3 600 500 65 35 22 25 35 50 30 18 25 35 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1 FCN 15-100 2, 3 600 500 150 65 25 30 42 85 50 22 30 42 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1 FCH 15-100 2, 3 600 500 200 100 35 42 65 100 80 36 42 65 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1 FCL 15-100 2, 3 600 500 200 150 42 65 80 200 150 50 65 80 6.4 (162.6) 3.0 (76.2) 3.2 (81.3) 2.5 lb/1 FB 100 Amp Frame; Current Limiting (UL/cUL File No. E-11592) Maximum UL Listed Interrupting Ratings - Approx. Circuit Voltage rms Symmetrical Amperes (in Thousands) Ship Breaker Ampere No. Rating Vac Dimensions in. (mm.) Wt./Std. Type Rating Poles AC DC 240 277 347 480 600/347 H W D Pack 1 600/347 — 35 35 22 — — 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1 FBV 15-100 2 600/347 — 65 — — 35 22 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1 3 600/347 — 65 — — 35 22 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1 1 600/347 — 65 65 25 — — 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1 FBN 15-100 2 600/347 — 150 — — 65 25 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1 3 600/347 — 150 — — 65 25 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1 1 600/347 — 100 100 35 — — 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1 FBH 15-100 2 600/347 — 200 — — 100 35 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1 3 600/347 — 200 — — 100 35 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1 1 600/347 — 100 150 42 — — 6.45 (163.8) 1.36 (34.5) 3.28 (83.3) 1.1 lb/1 FBL 15-100 2 600/347 — 200 — — 150 42 6.45 (163.8) 2.74 (69.6) 3.28 (83.3) 2.6 lb/1 3 600/347 — 200 — — 150 42 6.45 (163.8) 4.11 (104.4) 3.28 (83.3) 3.3 lb/1 FE 250 Amp Frame; Current Limiting (UL/cUL File No. E-11592) Maximum UL Listed Interrupting Ratings - Approx. Circuit Voltage rms Symmetrical Amperes (in Thousands) Ship Breaker Ampere No. Rating Vac Dimensions in. (mm.) Wt./Std. Type Rating Poles AC DC 240 480 600 H W D Pack FEN 250 2 480 - 150 65 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1 FEN 250 3 480 - 150 65 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1 FEH 250 2 480 - 200 100 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1 FEH 250 3 480 - 200 100 - 6.70 (170.1) 4.11 (104.4) 3.52 (89.5) 4.5 lb/1 FG 600 Amp Frame; Current Limiting (UL/cUL File No. E-11592) Maximum UL Listed Interrupting Ratings - EN 60947-2 Interrupting Ratings, Approx. Circuit Voltage rms Symmetrical Amperes (in Thousands) Icu, Amperes (in Thousands) Ship Breaker Ampere No. Rating Vac Vac Dimensions in. (mm.) Wt./Std. Type Rating Poles AC DC 240 480 600 240 400-415 690 H W D Pack FGN 250-600 2 600 — 150 65 25 — — — 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1 3 600 — 150 65 25 85 50 10 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1 FGH 250-600 2 600 — 200 100 35 — — — 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1 3 600 — 200 100 35 100 80 22 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1 FGL 250-600 2 600 — 200 150 42 — — — 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1 3 600 — 200 150 42 200 150 40 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1 FGP 250-600 2 600 — 200 200 65 — — — 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1 3 600 — 200 200 65 — — — 10.31 (262.0) 5.46 (138.7) 4.53 (115.0) 22 lb/1

Rev. 1/19 Data subject to change without notice

GE Products BuyLog

go.abb/industrial

6-10

Made with FlippingBook - Online magazine maker