GE Products BuyLog Smart Catalog
Molded Case Circuit Breakers
Section 6
Q-Line Circuit Breakers Plug-in Circuit Breakers 240V Class
THQL and THHQL 120/240 Vac, Ground Fault with Self-Test Feature # of Ampere 120/240 Vac Poles Rating Wire Range 1 1 15 14-8 Cu/12-8 Al 10kA 1 20 14-8 Cu/12-8 Al 10kA 1 25 14-8 Cu/12-8 Al 10kA 1 30 14-8 Cu/12-8 Al 10kA 2 15 14-8 Cu/12-8 Al 10kA 2 20 14-8 Cu/12-8 Al 10kA 2 25 14-8 Cu/12-8 Al 10kA 2 30 14-8 Cu/12-8 Al 10kA 2 40 8-3 Cu/8-3 Al 10kA 2 50 8-3 Cu/8-3 Al 10kA 1 15 14-8 Cu/12-8 Al 22kA 1 20 14-8 Cu/12-8 Al 22kA 1 25 14-8 Cu/12-8 Al 22kA 1 30 14-8 Cu/12-8 Al 22kA 2 15 14-8 Cu/12-8 Al 22kA 2 20 14-8 Cu/12-8 Al 22kA 2 25 14-8 Cu/12-8 Al 22kA 2 30 14-8 Cu/12-8 Al 22kA THQL and THHQL 120 Vac, Equipment Protection Ground Fault Circuit Breakers Internal Common Trip # of Ampere 120 Vac Poles Rating Wire Range 1 1 15 14-8 Cu/12-8 Al 10kA 1 20 14-8 Cu/12-8 Al 10kA 1 30 14-8 Cu/12-8 Al 10kA THQL and THHQL 120/240 Vac or 208Y/120 Vac, Equipment Protection Ground Fault Circuit Breakers # of Ampere 120/240 Vac or 208Y/120 Poles Rating Wire Range 1 2 15 14-8 Cu/12-8 Al 10kA 2 20 14-8 Cu/12-8 Al 10kA 2 30 14-8 Cu/12-8 Al 10kA 2 15 14-8 Cu/12-8 Al 22kA 2 20 14-8 Cu/12-8 Al 22kA THQL and THHQL 120/240 Vac, High Intensity Discharge Lighting Loads # of Ampere 120/240 Vac Poles Rating Wire Range 1
Interrupting Rating Product Number
THQL1115GFT THQL1120GFT THQL1125GFT THQL1130GFT THQL2115GFT THQL2120GFT THQL2125GFT THQL2130GFT THQL2140GFT 3 THQL2150GFT 3 THHQL1115GFT THHQL1120GFT THHQL1125GFT THHQL1130GFT THHQL2115GFT THHQL2120GFT THHQL2125GFT THHQL2130GFT
THQL1120GFT
Interrupting Rating Product Number
THQL1115GFEP THQL1120GFEP THQL1130GFEP
THQL1120GFEP
Interrupting Rating Product Number
THQL2115GFEP THQL2120GFEP THQL2130GFEP THHQL2115GFEP THHQL2120GFEP
Interrupting Rating Product Number
THQL1115HID 2 THQL1120HID 2 THQL1125HID THQL1130HID THHQL1115HID 2 THHQL1120HID 2 THHQL1125HID THHQL1130HID
1 15 14-8 Cu/12-8 Al 10kA 1 20 14-8 Cu/12-8 Al 10kA 1 25 14-8 Cu/12-8 Al 10kA 1 30 14-8 Cu/12-8 Al 10kA 1 15 14-8 Cu/12-8 Al 22kA 1 20 14-8 Cu/12-8 Al 22kA 1 25 14-8 Cu/12-8 Al 22kA 1 30 14-8 Cu/12-8 Al 22kA
THQL2115GFEP
UL listed as HID.
THQL and THHQL 120/240 Vac, Internal Common Trip For High Intensity Discharge Lighting Loads # of Ampere 120/240 Vac Poles Rating Wire Range 1 2 15 14-8 Cu/12-8 Al 10kA 2 20 14-8 Cu/12-8 Al 10kA 2 25 14-8 Cu/12-8 Al 10kA 2 30 14-8 Cu/12-8 Al 10kA 2 15 14-8 Cu/12-8 Al 22kA 2 20 14-8 Cu/12-8 Al 22kA 2 25 14-8 Cu/12-8 Al 22kA 2 30 14-8 Cu/12-8 Al 22kA UL listed as HID. 1Solid or stranded for 14-10 AWG. 2 UL listed as SWD (switching duty). Suitable for 120 Vac fluorescent lighting loads. 3 UL & CSA
Interrupting Rating Product Number
THQL2115HID THQL2120HID THQL2125HID THQL2130HID THHQL2115HID THHQL2120HID THHQL2125HID THHQL2130HID
THQL2120HID
Rev. 1/19 Data subject to change without notice
GE Products BuyLog
go.abb/industrial
6-16
Made with FlippingBook - Online magazine maker