Circuit Breaker Enclosures

Section 7

NEMA Type 1

—Suitable for use as service equipment (SE) as noted. —60°C/75°C conductor ratings —Short circuit ratings are equal to the rating of the installed breaker.

To order enclosed or accessorized circuit breakers, a configurator is available at: www.geelitenet.com (EliteNet)

Type 1, Indoor Surface or Flush Mounting

NEMA Type 1

For Enclosures with Certifications Product Number Suffix Options (Mounting) For 3P4W Enclosures Ground Fault Protection

Max.

Surface,

Ampere No. of UL

cUL

Blank

Neutral Neutral Product Neutral Sensor

Rating Frame Type Poles SE cUL SE 1 CSA Prefix

Flush Surface End Wall 2

Product Number Number 3

for Ground Fault

TQL70_ 4 TQL100_ 4 TQL125_ TQC100_ 4

70 THQL, TXQL, THQL-GF 1, 2, 3 • 100 THQL, TXQL, THQL-GF 1, 2, 3 • 125 THQL 2 • 100 THQC, THHQC, TXQC 1, 2, 3 • 100 SE150, THED, TED, TEB 2, 3 • 150 SE150, THED, TED 2, 3 • 225 TQD, THQD 2, 3 • 250 SF250 2, 3 •

– – • – – • – – – – – • – – • – – • – – • – – •

F S F S F S F S F S F S F S F S

– Included – – Included – – Included – – Included – SB Included – SB Included – - Included –

– – – – – – – –

TE100_ TE150_

TQD225_

SB TNIA225 5

SF250_

FEGS0025 FEGS0060 FEGS0125 FEGS0150 FEGS0250 FEGS0025 FEGS0060 FEGS0125 FEGS0150 FEGS0250 TSRG201 TSRG204 TSRG206 FGGS0250 FGGS0400 FGGS0600 PGGS0250 PGGS0400 PGGS0600 TSKG408 TSKG410 TSKG412 – –

SB TNIA225 5

250 FE250 2, 3 •

• – –

FE250_

F S

TNIA250EGF

SB TNIA225 5

• – –

PE250_

F S

250 PE250 2,3 •

TNIA250EGF

TJ400_ 6 TJ600_

400 TJD, TJJ, TJK, THJK 2, 3 • 600 TJK, THJK 2, 3 •

– – • – – •

F S F S

- TNIA400 – - TNIA600 –

400 SG400 2, 3 •

– – •

SG400_

F S

SB TNIA400 TNIA400VG

600 SG600 2, 3 •

– – •

SG600_

F S

SB TNIA600 TNIA600VG

TNIA400 TNIA600

TNIA400GGF

600 FG600 2, 3 •

• – –

FG600_

F S

SB

TNIA600GGF

TNIA400 TNIA600

TNIA400GGF

600 PG600 2,3 •

• – –

PG600_

F S

SB

TNIA600GF

TNIA400

TNIA600 TNIA800G

TK4V1200_ 7, 8

1200 SK1200 2, 3 •

– – •

F S

SB

TNIA800

TNIA1200G

TNIA1200 TNIAC1200

1 cUL Listed - Suitable for use as service equipment. 2 Enclosures with blank end walls (no Knockouts) and a feature to adjust the instantaneous setting on Spectra Circuit breakers.

3 Neutral for ground fault required to mount neutral sensor in enclosure. 4 3-Pole breakers with an accessory cannot be installed in these enclosures. 5 For 250A rating, use copper cable only. 6 Suitable for parallel 250 kcmil maximum. If larger cable is required, use 600A enclosure. 7 Not suitable for 100% rated 1200A SK breakers. 8 Suitable for parallel 500 kcmil maximum.

Rev. 1/19 Data subject to change without notice