GE Products BuyLog Smart Catalog
Circuit Breaker Enclosures
Section 7
NEMA Type 1
—Suitable for use as service equipment (SE) as noted. —60°C/75°C conductor ratings —Short circuit ratings are equal to the rating of the installed breaker.
To order enclosed or accessorized circuit breakers, a configurator is available at: www.geelitenet.com (EliteNet)
Type 1, Indoor Surface or Flush Mounting
NEMA Type 1
For Enclosures with Certifications Product Number Suffix Options (Mounting) For 3P4W Enclosures Ground Fault Protection
Max.
Surface,
Ampere No. of UL
cUL
Blank
Neutral Neutral Product Neutral Sensor
Rating Frame Type Poles SE cUL SE 1 CSA Prefix
Flush Surface End Wall 2
Product Number Number 3
for Ground Fault
TQL70_ 4 TQL100_ 4 TQL125_ TQC100_ 4
70 THQL, TXQL, THQL-GF 1, 2, 3 • 100 THQL, TXQL, THQL-GF 1, 2, 3 • 125 THQL 2 • 100 THQC, THHQC, TXQC 1, 2, 3 • 100 SE150, THED, TED, TEB 2, 3 • 150 SE150, THED, TED 2, 3 • 225 TQD, THQD 2, 3 • 250 SF250 2, 3 •
– – • – – • – – – – – • – – • – – • – – • – – •
F S F S F S F S F S F S F S F S
– Included – – Included – – Included – – Included – SB Included – SB Included – - Included –
– – – – – – – –
TE100_ TE150_
TQD225_
SB TNIA225 5
SF250_
–
FEGS0025 FEGS0060 FEGS0125 FEGS0150 FEGS0250 FEGS0025 FEGS0060 FEGS0125 FEGS0150 FEGS0250 TSRG201 TSRG204 TSRG206 FGGS0250 FGGS0400 FGGS0600 PGGS0250 PGGS0400 PGGS0600 TSKG408 TSKG410 TSKG412 – –
SB TNIA225 5
250 FE250 2, 3 •
• – –
FE250_
F S
TNIA250EGF
SB TNIA225 5
• – –
PE250_
F S
250 PE250 2,3 •
TNIA250EGF
TJ400_ 6 TJ600_
400 TJD, TJJ, TJK, THJK 2, 3 • 600 TJK, THJK 2, 3 •
– – • – – •
F S F S
- TNIA400 – - TNIA600 –
400 SG400 2, 3 •
– – •
SG400_
F S
SB TNIA400 TNIA400VG
600 SG600 2, 3 •
– – •
SG600_
F S
SB TNIA600 TNIA600VG
TNIA400 TNIA600
TNIA400GGF
600 FG600 2, 3 •
• – –
FG600_
F S
SB
TNIA600GGF
TNIA400 TNIA600
TNIA400GGF
600 PG600 2,3 •
• – –
PG600_
F S
SB
TNIA600GF
TNIA400
TNIA600 TNIA800G
TK4V1200_ 7, 8
1200 SK1200 2, 3 •
– – •
F S
SB
TNIA800
TNIA1200G
TNIA1200 TNIAC1200
1 cUL Listed - Suitable for use as service equipment. 2 Enclosures with blank end walls (no Knockouts) and a feature to adjust the instantaneous setting on Spectra Circuit breakers.
3 Neutral for ground fault required to mount neutral sensor in enclosure. 4 3-Pole breakers with an accessory cannot be installed in these enclosures. 5 For 250A rating, use copper cable only. 6 Suitable for parallel 250 kcmil maximum. If larger cable is required, use 600A enclosure. 7 Not suitable for 100% rated 1200A SK breakers. 8 Suitable for parallel 500 kcmil maximum.
Rev. 1/19 Data subject to change without notice
GE Products BuyLog
go.abb/industrial
7-2