GE Products BuyLog Smart Catalog

Low Voltage Power & Insulated Case Circuit Breakers Section 8

Power Break ™ II Circuit Breakers Neutral Current Sensors and POWER LEADER Accessories

Neutral Current Sensors 1

Portable Test Set The portable, battery-powered test kit provides self-tests and functional trip/no trip tests. It also provides defeat of the ground fault function and can be used in conjunction with high current test equipment. Interface is via a plug on the front of the trip unit and test can be conducted with the breaker in service. Test kits use either 120 Vac power source or internal batteries (not included). Description Trip Unit Type Product Number 1 Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating. 3 At time of initial product release, the 1200A new HPC Switch was using 1600A installed sensors and a 1200A rating plug. Later models may or may not use 1200A phase sensors. Match Neutral sensor tap to HPC sensor rating. 3 Outline Drawing 10112973P1. Portable Battery Pack The hand-held Portable Battery Pack provides an independent power source for EntelliGuard ™ TU, micro EntelliGuard ™ , MicroVersaTrip ™ Plus and MicroVersaTrip ™ PM trip units as an alternative to a test set. The battery pack is used to power up the trip unit to set or adjust trip set points when the breaker is on the bench or otherwise not powered up. For micro EntelliGuard ™ trip units, the battery pack connects to the trip unit through the 15-pin connector. A battery pack adapter cable is required. For MicroVersaTrip ™ Plus and MicroVersaTrip ™ PM trip units, the battery pack connects to the trip unit through the rating plug test jack. The battery pack requires three standard 9 Vdc alkaline batteries (not included). Description Product Number Portable Battery Pack TVPBP EntelliGuard ™ TU, micro EntelliGuard ™ Battery Pack Adapter Cable TVPBPACC Circuit Breaker Neutral Sensor Breaker Frame Sensor Rating Rating or Tap Product (Amperes) (Amperes) Settings (Amperes) Number 200 200 TSVG302 800 400 400/200 TSVG304A 400 600/300 2 TSVG306A 800-1600 800 800/400 TSVG308A 1000 800/400 2 TSVG808A 1600 1000 1000/500 TSVG810A 1600 1200/600 2 TSVG812A 1600 1600/1000 TSVG816A 2000 2000 2000/1000 TSVG820A 1000 800/400 2 TSVG808A 1000 1000/500 TSVG810A 1000 1200/600 2 TSVG812A 3000 1000 1600/1000 2 TSVG816A 2000 2000/1200 TSVG820A 2500 2500/1800 TSVG825A 3000 3000/2400 TSVG830A 4000 4000 4000/3000 TSVG940A 1 Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating. 2 For use with multiple source ground fault protection schemes. Rating does not match EntelliGuard ™ TU and MicroVersaTrip ™ Plus or PM frame sensor. Neutral Current Sensors 1 Breaker Breaker Neutral Sensor Product Inside Frame Sensor Rating Rating or Tap Number of Diameter (Amperes) (Amperes) Settings (Amperes) Window Sensor (inches) 800 800 800/400 SSVG808W 4.25 1200 1200 3 2000/1200 SSVG820W 5.63 1600 3 1600/1000 SSVG816W 5.63 1600 1600 1600/1000 SSVG816W 5.63 2000 2000 2000/1200 3 SSVG820W 5.63 2500 2500 2500/1800 SSVG825W 5.63 3000 3000 4000/3000 SSVG940W 6.50 4000 4000 4000/3000 SSVG940W 6.50 Portable Test Set MicroVersaTrip ™ only TVRMS2 EntelliGuard ™ TU, micro EntelliGuard ™ only GTUTK20

Neutral Current Sensor

SSVG Neutral Current Sensors

POWER LEADER ™ Power Supplies Power supply for furnishing 24Vdc control power for EntelliGuard ™ TU, MicroVersaTrip ™ Plus and PM trip units. System Product Description Requirements Number

1.5 ampere power supply Price one PLPS4G01 for each line-up. 45 trip units 4

Input power, 100VA and 100 ft. maximum. (85-265Vac or 100-370Vdc) PLPS4G01 4 20 trip units maximum for EntelliGuard ™ TU

Reference Instructions GEH-6492

POWER LEADER ™ Voltage Conditioner Conditions and scales 120 Vac to 1.76 Vac for use by the trip unit for voltage sensing. Provides transient protection. Voltage conditioners require isolation PTs. System Product Description Requirements Number Supplies isolated bus voltage signal to EntelliGuard ™ TU and One set of 3 voltage conditioners MicroVersaTrip ™ PM required for each voltage sensing trip units. location. PTs also required. PLVC1G01

Reference Instructions GEH-5946

Rating Plug Removal Tool

Product Number TRTOOL

Rev. 1/19 Data subject to change without notice

go.abb/industrial

GE Products BuyLog