GE Products BuyLog Smart Catalog

Panelboards Lighting Distribution Panelboards Fusible Switches Load and Interrupting Ratings

Section 11

Spectra ™ Series Neutral Kits —Includes mechanical lugs and bonding strap. —250 to 600A neutral kits can be converted to dual main version by doubling the main lug quantity using lug kits (see Accessories). —Main lug on neutral kit can be converted to compression main using AMKP lug kit.

Standard Neutral (Single Main Lug) 4

Dual Main Neutral 5

Product Number

Accepts Wire Qty.

Accepts Wire Size (Cu/Al)

Product Number

Accepts Wire Qty.

Accepts Wire Size (Cu/Al)

Amps

2 (Main)

#2 - 600kcmil

2 (Main)

#2 - 600kcmil

#14 - 2/0

16

#14 - 2/0

16

250

ANKN400

ANKN400

5

#6 - 300kcmil

5

#6 - 300kcmil

24

#14 - #4

24

#14 - #4

#2 - 600kcmil

8 (Main)

#2 - 600kcmil

2 (Main)

16

#14 - 2/0

9

#14 - 2/0

400

ANKN400

ANKN120

5

#6 - 300kcmil

10

#6 - 300kcmil

24

#14 - #4

10

#14 - #4

8 (Main)

#2 - 600kcmil

8 (Main)

#2 - 600kcmil

9

#14 - 2/0

9

#14 - 2/0

600

ANKN120

ANKN120

10

#6 - 300kcmil

10

#6 - 300kcmil

10

#14 - #4

10

#14 - #4

#2 - 600kcmil

8 (Main)

#2 - 500kcmil

8 (Main)

9

#14 - 2/0

8

#14 - 2/0

800

ANKN120

ANK800D

10

#6 - 300kcmil

10

#6 - 300kcmil

10

#14 - #4

4

#2 - 500kcmil

#2 - 600kcmil

8 (Main)

#2 - 500kcmil

8 (Main)

9

#14 - 2/0

8

#14 - 2/0

ANK120D

1200

ANKN120

10

#6 - 300kcmil

10

#6 - 300kcmil

10

#14 - #4

4

#2 - 500kcmil

4 For 3ph, 4W single-section panelboards, use a standard neutral. 5 For 3ph, 4W multi-section panelboards, use a standard neutral on the last section, and a dual main neutral on the first and middle sections.

smallest, lowest amperage furthest from the main incoming. The spaces, if any, will follow after the breakers. All main breakers are mounted horizontally and incoming lugs are, as a standard and if not specified, always oriented to the left gutter regardless if top or bottom feed. If 2 or more large branch breakers (SK, SG single mounted) are supplied with the board then the factory will start the first breaker with the lugs to the right and the second breaker with lugs to left and will continue staggering them until all have been installed. If any further clarification is needed, please con- tact your local GE representative.

Breaker Side Gutter Space

ENCLOSURE SIDE WALL

A

EY, QB

EY, QB

B C

T(H)E, SE, FC, FE

T(H)E, SE, FC, FE

T(H)QD

T(H)QD

D

T(H)J, SF

T(H)J, SF

E

SG, FG

SG, FG

J

FE

F

T(H)J, SF

Enclosure Width

Letter Reference

27

31

36

40

44

G

SG, FG

A B C D

7.88

9.88

12.38

14.38

16.38

5.75

7.75

10.25

12.25

14.25

T(H)K, SK

H

5.63

7.63

10.13

12.13

14.13

N/A

5.50

8

10

12

E

N/A

N /A

6.38

8.38

10.38

ALL DIMENSIONS ARE FROM FACE OF LUG, SHOWN IN INCHES AND ± .250 Single mounted devices as branch or main Breakers are arranged, as a standard and if not specified, with largest and highest amperage closest to main incoming and the

F

8.88

10.88

13.38

15.38

17.38

G H

8.13

10.13

12.63

14.63

16.63

N/A

N /A

N/A

12.63

14.63

J

Breaker not available at time of printing

Rev. 1/19 Data subject to change without notice