GE Products BuyLog Smart Catalog

Uninterruptible Power Supplies Energy Connections TLE Series UPS 225 to 1000 kVA

Section 20

The TLE Series UPS is one of the best performing three-phase UPS systems providing critical power protection for a wide range of applications. The TLE Series operates in VFI mode (Voltage Frequency Independent) and has been developed to satisfy the growing request of high efficiency through an innovative control algorithm with 3-level inverter technology. This innovative product provides best-in-class efficiency in double conversion mode as well as eBoost ™ operating mode. The TLE Series is developed using GE’s Design for Six Sigma methodology to help ensure that the product fully meets customer requirements and expectations. The TLE Series UPS provides industry-leading reliability, efficiency, clean input performance and unity power factor at output. Reliability can be further increased by paralleling more units utilizing GE’s unique RPA ™ (Redundant Parallel Architecture) technology. Through their complete life cycle, all GE UPS systems are fully supported by service teams which provide world-class, 24x7 preventive and corrective services, training and application expertise. Innovative Technology & Best-in-Class Efficiency The TLE Series UPS brings the latest power conversion technology to the marketplace, using a three-level inverter design and a multimode architecture that makes real time decisions between premium protection mode and premium eYciency mode. The TLE Series UPS was developed using GE’s Design for Six Sigma (DFSS) methodology to ensure that the product meets customer require- ments for reliability and quality. Technology at Its Best —Highly reliable and efficient tri-level conversion —Automatic or manual multi-mode operation “Best of Both Worlds” Operating Efficiency —97% Efficiency in premium protection mode (double conversion) —99% Efficiency in premium energy save mode (eBoost)

Electrical Environment Optimization —Unity (1.0) Output Power Factor —High (0.99) Input Power Factor —Less than 5% Input Current Harmonic Distortion Physical Environment Optimization —Small footprint —Front access only design for maintenance

—Multi-Module “cable saver” design to allow +/- 25% differential of cable lengths between UPS modules and I/O parallel buses

GE Multi-Mode Technology Concept

Rev. 1/19 Data subject to change without notice

GE Products BuyLog

go.abb/industrial

20-52

Made with FlippingBook - Online magazine maker