2019 Hardware Catalog

CIRCUIT BREAKERS

1.800.394.0019

146

Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. #14 - 8 wire range 15 to 30 amp, #14 - 2 wire range 40 to 70 amp, #10 - 1/0 wire range 100 amp. UL Listed, HACR rated, meets NEMA standards and federal specifications, CSA certified. 120/240 volt. 10,000 AIR. 3/4" per pole. Common Trip (Instantaneous). CUTLER-HAMMER® CH230 Miniature Circuit Breaker

ITEM#

SIZE TYPE Volt

Amp # Poles Mount Model COUNT UOM

CUT-CH230 1-1/2" CH,

EA

Miniature 120/240 30 2-Pole Plug-

In CH230 1

CUT-CH230

Combination type arc fault circuit interrupter includes all of the protection offered by the branch feeder AFCI (mitigation of parallel arcing faults in the complete circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. Wire Size: #14-8 AWG Cu/Al . EATON® BR115CAFA Arc Fault Combination Circuit Breaker

ELECTRICAL

710017

ITEM# 710017

SIZE TYPE

Volt

Amp # Poles Mount

Model

COUNT UOM

1" BR, Arc Fault Combination 120/240 VAC 15 1-Pole Plug-In BRP115AF 1

EA

For use in Eaton Type CH load centers, spa, pool and meter breaker panels. Trips to OFF position and simple 1-step reset breaker feature eliminates the need to turn the breaker OFF before turning to the ON position. Trip flag visibly indicates breaker status. Carries listing for HACR applications as well as switch duty rated. UL listed. Flag visually confirms “Tripped” status, making it easy for the homeowner to identify. Tri-Drive screw accepts flat, Robertson or Phillips drivers, making it easier for electricians to install. Space-saving ¾-inch design accommodates more breakers per panel. Limited lifetime warranty. EATON® CH Circuit Breakers with Trip Flag

ITEM# SIZE TYPE Volt

Amp # Poles Mount Model COUNT UOM

203745 3/4" CH 120/240 15 1-Pole Plug-In CH115 1 203746 3/4" CH 120/240 20 1-Pole Plug-In CH120 1

EA EA

Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space, 1/2" per pole. UL Listed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 volt fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32" height x 1/2" width x 2-3/8" depth. 120/240 volt; 10,000 AIR. Trips to the center position. Toggle switch. ANSI Specified, CSA Certified, UL Listed. GE® THQP115 Single Pole Q-Line Standard Circuit Breaker

ITEM# SIZE TYPE Volt

Amp # Poles Mount Model

COUNT UOM

608001 1/2" THQP 120/240

EA

VAC 15 1-Pole Plug-In THQP115 1

608001

If you need it, we can get it!

www.dayconintegratedservices.com | 1.800.394.0019

Made with FlippingBook - professional solution for displaying marketing and sales documents online