STC - Erection Manual

STC

®

S nap T ight C onstruction

ERECTION SEQUENCE

STEP 8 cont'd

3"

2

1

ENDLAP - PANEL

Remove awl and insert in the hole nearest the male leg. Install 1/4"-14 x 1-1/4" WT fastener in the hole by the female leg. All holes in the upper and lower panels and the back-up plate should now be aligned with each other. NOTE Step 8 applies only where more than one panel is used in a single slope.

1/4"-14 X 1 1/4" WT

5

Install 1/4"-14 x 1-1/4" WT fasteners in sequence 2, 3, 4 and the hole left by the awl after it is removed (5). Next, install 1/4"-14 x 1-1/4" WT fastener in positions 6 and 7.

6

1"

7

1

4

8 3 9

2

FASTENER SEQUENCE FIRST RUN - ENDLAP

1/4"-14 X 1 1/4" WT

FIELD LOCATED

To ensure that the male legs do not separate at the panel endlap, clamp the horizontal ledge with C-locking pliers until the endlap is fastened together.

IMPORTANT: TRI-BEAD TAPE MASTIC STRIP ESSENTIAL FOR WEATHER TIGHTNESS

IMPORTANT Apply Tri-Bead tape mastic over the notched portion of these male legs.

Repeat the endlap procedures as required for each panel until the ridge or high eave is reached.

SUBJECT TO CHANGE WITHOUT NOTICE

Version 7.1

STC-29

Made with FlippingBook - Online catalogs