STC - Erection Manual

STC

®

S nap T ight C onstruction

DETAILS HIGH EAVE HEIGHT CHANGE TRIM * WALL PANEL

SL

* Provide air gap of 1/4" minimum at bottom of panel to avoid corrosion.

HEIGHT CHANGE TRIM (LHET) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) INSIDE CLOSURE

1/4"

TRI-BEAD TAPE MASTIC 1/4"-14 X 7/8" WT

1/4"-14 X 1 1/4" WT (9 PER PANEL)

OUTSIDE CLOSURE PRE-CUT TRI-BEAD TAPE MASTIC

ROOF CLIP AND FASTENERS (SEE ROOF PANELING PLAN)

STC PANEL

BACK-UP PLATE

INSULATION

PURLIN

4"

8"

HEIGHT CHANGE TRIM

1½"

1½"

1½"

1½"

5 ¼"

24" Panels = 4 SPACES AT 5 ¼" 18" Panels = 3 SPACES AT 5"

Refer to erection drawing General Details for expansion joint installation instructions if required.

1/4"-14 X 7/8" WT

OUTSIDE CLOSURE

HEIGHT CHANGE TRIM FASTENER SPACING

SUBJECT TO CHANGE WITHOUT NOTICE

Version 7.1

STC-55

Made with FlippingBook - Online catalogs