PW Head PPE Range
MARKINGS AND STANDARDS
PS55
PW47
T400
The PPE Regulation (EU) 2016/425 has a risk approach which defines harmful noise as a risk that may cause very serious hearing injuries. As a result, the Regulation has recategorized hearing protection from Category 2 Risk PPE (Intermediate) to Category 3 Risk (Complex). The Control of Noise at Work Regulations 2005 The Noise Regulation 2005 requires employers to prevent or reduce risks to health and safety from exposure to noise at work. It asks to take specific actions and defines action levels and limit values of exposure to noise:
EN 352-1:2020 Hearing Protectors - Ear Muffs EN 352-2:2020 Hearing Protectors - Ear Plugs EN 352-3:2020 Hearing Protectors - Helmet Mounted Ear Muffs
Daily / Weekly average exposure to noise
Peak Sound pressure
LOWER EXPOSURE ACTION VALUES
80dB
135dB
All these standards establish require ments with regards to the manufacture, design, performances and test methods.
UPPER EXPOSURE ACTION VALUES
85dB
137dB
LEVELS OF NOISE EXPOSURE THAT MUST NEVER BE EXCEEDED
87dB
140db
SNR (Single Number Rating): Single average value of attenuation.
How To Protect Yourself? 4 Steps To Choose The Appropriate Hearing Protection.
HML : Attenuation values expressed in terms of average levels of frequencies: H : Attenuation of PPE at high fre quencies (pitched noises). M : Attenuation of PPE at medium frequencies. L : Attenuation of PPE at low fre quencies (bass sounds).
1. Identify the nature of the noise: stable, fluctuating, intermittent or pulse. 2. Measure the noise at the working station: intensity (dB) and volume (Hz). 3. Determine the exposure time. 4.Calculate the required attenuation needed. The attenuation level offered by the hearing protector should bring the noise to a level that is not harmful to health whilst avoiding over-protection which would isolate the worker. Hearing protectors that reduce the level at the ear to below 70 dB should be avoided.
DECIBEL SCALE (dBA)
ANSI S3.19 1974 American National Standard - Methods for Hearing Protection Measurement This standard specifies the test method for determining the level of noise attenuation (NRR Noise Reduction Rating) of the hearing protection, as recommended by the EPA (U.S. Environmental Protection Agency).
160
12 Gauge Shotgun - 165 dB Peak
150
140
Jet Takeoff - 140 dB
130
120
Pneumatic Riveter - 124 dB
110
Chainsaw - 110 dB
Hammer Drill - 114 dB
100
Rock Concert - 105 dB
Motorcycle - 100 dB
90
Tractor/Hand Drill - 97 dB
Lawn Mower - 90 dB
AS/NZS 1270 2002 Australian and New Zealand standard for Hearing Protectors Devices. This standard specifies the attenuation offered by a hearing protection device through Sound Level Conversion (SLC80).
80
Vacuum Cleaner - 80 dB
70
City Traffic - 78 dB
60
Conversation- 65 dB
Air Conditioning - 60 dB
50
Floor Fan- 50 dB
40
Refrigerator Hum - 40 dB
Electric Transformer - 45 dB
30
Rustling Leaves - 30 dB
20
10
766|
12_EUROW_PPE_PART 1_V18.indd 766
24/08/2023 14:42
Made with FlippingBook - Online Brochure Maker