Technical Specifications (continued)

Temperature:

Compliance: Environmental: RoHS Safety:

-20°C to 65°C (IEEE 1613-2009)

Humidity:

0% to 95% non-condensing

Management:

IEC60825-1 & 2 for Laser Safety

Windows™-based NMS, HP XView EMS for module Remote Management & Software Update: Yes SNMP Control & Monitoring: Yes System Event Logging: Yes Routing for Data Command Channel: RIP v1/2, OSPF SFP DDMI: Multi Source Agreement for SFPs (SFF-8472) Power consumption: 14 Watts maximum

Immunity: EN 61000-4-6:2009 for conducted immunity IEEE 1613-2009 class 2; IEEE C37.90.2-2004; EN 61000-4-3:2006 for radiated immunity Front panel: IEEE 1613-2009 class 2; IEEE C37.90.3-2001; IEC 61000-4-2:2008 for ESD Power Supply, Alarm Contacts, and T1/ E1 ports: IEEE 1613-2009 class 2; IEEE C37.90.1-2002; IEC 61000-4-4:2004; IEC 60255-22-1:2005 for Oscillatory SWC Shock & Vibration: Stationary Vibration sinusiodal, IEC 60870-2-2 Section 4, Class Cm Shock Emmissions: EN 55022 Class A; FCC Part 15 Class A

Upgrade Information

The IMUX 2000s SONET/SDH Module can be purchased two ways: as an upgrade to existing systems or as a standalone. The module kit is a complete package to upgrade an installed IMUX 2000 T1/ E1 multiplexer and/or IMUX 2000 T1/ E1 MDACS system. RFL will provide technical services to provide an engineered solution that will maintain the existing payload and expand the network. The following systems can be upgraded to use the IMUX 2000s SONET/SDH module: • IMUX 2000 T1/E1 Multiplexer Terminal End/ Drop & Insert with CM-4 • IMUX 2000 T1/E1 MDACS Multiplexer • MUX 2000 E1 Multiplexer with CM-6B

The upgrade kit will include the 2000s SONET/SDH module, the Module Adapter for T1/E1 connections, new front panel and all necessary cables for management and external T1/E1 connections. Alternatively, the IMUX 2000s SONET/ SDH Module can also be supplied as a new fully integrated SONETor SDH system configured per the customer’s needs and requirements. This solution would be fully engineered, tested, documented, and ready to be commissioned right out of the box. For more information to determine if older IMUX 2000 T1 Multiplexer systems can be upgraded, please contact Sales and Application Engineering Group at RFL.