R016600x

Appendix A - Steam Generator Lifting Instruction

* * Clayton rigging instructions are typical. IT IS THE RESPOSIBILITY OF THE INSTALLER/CONTRACTOR TO HAVE PERSONNEL ON-SITE, WHO ARE TRAINED/CERTIFIED IN HOISTING AND RIGGING, VERIFY UNIT IS PROPERLY, SECURELY, AND SAFELY RIGGED BEFORE LIFTING. * Due to high center of gravity, safety cables must be used at ALL TIMES. DO NOT use safety cables for lifting.

Refer to applicable plan installation drawing for center-of-gravity (COG ) points.

Note 1: Minimum height for E154FF-354FF=14 ft. Note 2: E154FF-354FF maximum lifting weight is 9,800 lb. Note 3: DO NOT lift from plumbing.

Note 4–Fork Lift Option: Properly-sized fork lifts can be used with frame fork lift channels.

Typical rigging for steam/ fluid generators with flush-floor skid frames (illustration rotated 90 ° counterclockwise)

A-3

04/22/2016

R-16600 Rev. W1