Chromalox European Product Catalog
LIQUID HEATING / CHAUFFAGE DES LIQUIDES
FPF
Hazardous area (db eb) immersion heaters with flanges Thermoplongeurs sur brides pour zone explosive (db eb)
• Immersion heaters for industrial water or medium oil. • ATEX II 2 G - Ex db eb II C T1 - T6 certified for ambient temperature -50°C +40°C (+60°C with a longer stand off) • Stood-off painted terminal enclosure in cast iron. • 150 Ib ANSI carbon steel flange, 5” / 6” / 8” / 10” / or 12” • Ø11 Incloy 800 sheathed elements • Watts density 9.3 W /sq.cm or 3.9 W /sq.cm or 1.9W/ sq.cm • Pocket for optional sensor, thermostat, or cutout • Voltage 400V / 3Ph
• Thermoplongeurs pour chauffage d’eau industrielle ou d’huile de viscosité moyenne. • Certifiés ATEX II 2 G - Ex db eb II C T1 à T6 pour températures ambiantes de -50°C à +40°C (+60°C avec déport allongé) • Boîtier décalé en fonte peinte • Bride acier suivant standard ANSI 150 Ib 5” / 6” / 8” / 10” / or 12” • Eléments blindés Incoloy 800, Ø11mm • Charge 9,3 W/cm2 ou 3,9 W/cm2 ou 1.9W/cm² • Doigt de gant pour sonde, thermostat, ou limiteur optionnel • Alimentation 400V tri
Standard models with Watt density 9.3 W/sq.cm / Références standardisées avec charge de 9,3 W/cm 2
Length X Côte X (mm)
Length X Côte X (mm)
Weight Poids* kg
Weight Poids* kg
Output Puissance (KW)
Output Puissance (KW)
Flange size / Diamètre de la bride
Flange size / Diamètre de la bride
5”
6”
8”
10”
6”
8”
10”
12”
120
– – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –
– –
–
FPF12048/60 200,3
490 750 905
–
FPF00606/60
– – – – – – – – – – – – – – – –
– – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – – –
275 275 355 355 430 430 515 515 595 595 760 760 915 915
48,3 45,3 48,6 45,6 48,8 45,8 49,3 46,3 49,8 46,8 50,2 47,2 50,8 47,8 89,9 51,7 48,7 90,6 91,9 52,7 49,7 92,1 53,7 47,4 93,5 107 93,6 55,8 52,6 49 46
6
FPF12030/60
– – – – – – –
97,5 88,7 55,4
FPFA00606/60
–
FPF12024/60
– – – – – – –
–
FPF00906/60
9
FPF12012/60
– – – – – – –
1 730
FPFA00906/60
–
144
FPF14448/60 113,3
570 750
–
FPF01206/60
12
FPF14436/60
100,2
FPFA01206/60
–
FPF14418/60
1 395 2 055 1 730
90
–
FPF01506/60
FPF14412/60 FPF15015/60
86,4 87,2
15
FPFA01506/60
–
150 162 165 168 180
–
FPF01806/60
FPF16254/60 204,4
570 905
18
FPFA01806/60
–
FPF16537/60
– –
204,7
–
FPF02406/60
FPF16821/60
– –
1 395
92,3
24
FPFA02406/60
–
– –
FPF18045/60 115,9
735
–
FPF03006/60
FPF18030/60
– – – – –
1 075 1 720 2 055 1 720 1 075 1 395 1 720 1 720 1 060 1 395 1 060 2 045 1 720 1 380 2 045 2 045 1 380 1 380 2 045 2 045 1 705 2 045 2 030 2 030 2 030 2 030 890 890
102,5
30
FPF18018/60
– – –
93
FPFA03006/60
–
FPF18015/60
–
89,7 95,8
–
FPF03606/60
1 085 1 085
36
210 216 225 240
FPF21021/60
FPFA03606/60
– –
– – – –
FPF21636/60
106,1
45
–
FPF04518/60
505
– –
FPF22545/60 208,5
FPF04806/60
– –
1 405 1 405
48
FPF24048/60
210
FPFA04806/60
– – – – – – – – – – – –
FPF24030/60
– – –
107,3
54
– – – – – – – – – – – – – – –
FPF05418/60
585 420 505
FPF24024/60 FPF27027/60
– – –
98,6
–
FPF06030/60 104,5
270 288
101,4
FPF06024/60
– – – – – – – – – – – – – – – – –
FPF28848/60 214,1
60
FPF06006/60
– – – – – –
1 730 1 730
FPF28836/60
–
112
FPFA06006/60
324
– –
FPF32454/60 217,8
FPF07236/60 106,2
420 750
FPF32427/60
– –
105,8 115,1
330 360
FPF33033/60
FPF07218/60
72
–
FPF36045/60 219,6
FPF07206/60
2 055 2 055
FPF36030/60 FPF39633/60
– –
117,2 120,5
FPFA07206/60
396 408 432 468 480 504 540 612 684 720
82,5
FPF08233/60 106,8
505 750 585 905
– –
FPF40851/60 224,2 FPF43254/60 226,5
84
FPF08421/60
–
FPF09030/60
FPF43236/60 FPF46839/60
– –
212,8 216,1
FPF09018/60
90
FPF09009/60
– – –
1 790 1 730
–
FPF48048/60 229,8
FPFA09009/60
– –
FPF50442/60
–
219,4
FPF10836/60 109,2
585
– – – –
FPF54045/60 234,4 FPF61251/60 240,9 FPF68457/60 247,5 FPF72060/60 250,8
FPF10818/60
1 075 2 055 2 055
95,1
108
FPF10809/60
– –
57 54
FPFA10809/60
–
NOTA : Gamme également standardisée avec charge 3,9 W/cm2 pour huiles légères, éthylène glycol .... (gammes de puissance de 12 à 360 kW) - . Gamme également standardisée avec charge 1.9 W/cm² ( gamme de
NOTE: Also standardized range with Watts density 3.9 W/sq.cm for light oils, etylene glycol, ... (range 12 up to 360kW). Also standardized range with Watts density 1.9 W/sq.cm ( range 4.5 up to
puissance de 4.5 à 162 KW- NOUS CONSULTER Gamme également standardisée avec charge : 1.2 W/cm² pour huiles lourdes ( gamme de 4.5 à 120 KW) 2.3 W/cm² pour huiles moyennes (gamme de 6 à 180 KW)
162 KW) - CONSULT OUR SALES OFFICE Also standardized range with Watts density :
1.2 W/sq.cm for heavy oils ( range from 4.5 up to 120 KW) 2.3 W/sq.cm for medium oils ( range from 6 up to 180 KW) On request: • Standard design on 14” and 16” flanges (output up to 936 kW) • 300 to 2500 Ib ANSI flanges • Stainless steel enclosure Options: • Safety thermostat with automatic or manual rest • Pt 100 safety sensor • Thermocouple for skin temperature safety
Sur demande : • Conceptions standardisées sur brides 14” et 16” (puissances jusqu’à 936 kW) • Brides ANSI de 300 à 2500 Ib • Boîtier Inox Options : • Thermostat de sécurité à réarmement automatique ou manuel • Sonde de sécurité Pt100 • Thermocouple de sécurité température de peau
NOTA : ajouter la classe de température désirée (T1, T2, T3, T4, T5, ou T6) en fin de référence
NOTE: add the requested temperature class (T1, T2, T3, T4, T5, or T6) at the end on the reference
10 - C - 22
Made with FlippingBook - Online catalogs