BayMedical_Vol43_Issue1

Sterilization Indicator Strips

Indicators Sterilization

C ENT R A L S T E R I L E

TEST PACKS FOR PRE-VACUUM STERILIZERS

C ENT R A L S T E R I L E

OK STERILIZATION INDICATOR STRIPS • Monitor all critical sterilization parameters - steam, time, temperature • Designed to indicate incomplete steam penetration, presence of non-condensing gases or excessive air, inadequate temperature or time exposure • Pre-printed strips allows for quick and accurate visualization of the results • Successful sterilization is demonstrated by a dark arrow and K, resulting in the OK indicator

• Detects leaks and low temperature pressure conditions, wet steam, super-heated steam and non-condensible gases • Lead and heavy metal free; non toxic and safe to use • Lot number marked on packs and test sheets • Precise and clear color change indicators • Test sheet can be archived as a performance record; ink will not revert

SELF-CONTAINED DUO SPORE BIOLOGICAL INDICATOR TEST • For weekly or daily sterilizer monitoring and load monitoring during sterilization • Reliable results in 48 hours • D-values and Survival/Kill performance data supplied with each unit are compliant with US Pharmacopeia requirements • Test envelope contains 2 test strips, 1 control strip in two color separated pouches • Biological indicator for use in steam, ethylene oxide or dry heat cycles • Process using Tryptic Soy Broth (TSB) culture media in your facility

SELF-CONTAINED BIOLOGICAL INDICATORS • Available for steam or eO gas sterilizers • Process indicator on each vial • Distinctive color change of the indicator media for immediate and accurate reading

ITEM

DESCRIPTION

PK

$

ITEM

DESCRIPTION

SIZE

PK

$

• Incubation time: 24hrs/steam vials; 48hrs/eO gas vials • Color-coding caps and media: brown/steam; red/eO gas

C6-1000-00

Strate-Line Autoclave Tape

0.5625" x 4"

250

$18.95

C6-3025-01

Once-A-Day Vertose Test Pack

30

$148.95

• Universal indicator incubator designed for use with steam or eO gas vials • Incubator holds up to 13 vials for incubation plus one crushing cavity • Recommended temperatures: 57°C/steam; 37°C/eO gas; adjustable with toggle switch

ITEM

DESCRIPTION

PK

$

ITEM

DESCRIPTION

PK

$

C6-2690-06 C6-2690-07 C6-2690-08 C6-2690-65 C6-2690-95 C6-2690-96 C6-2690-97

C6-2000-00 C6-2000-01 C6-2001-01 C6-2010-00

Biological Indicator Test Strips & Growth Media Vials

25 25

$104.95 $119.95

Bi-OK SteamVials Bi-OK SteamVials Bi-OK EO Gas Vials

20

$75.95

Biological Indicator Growth Media Vials Biological Indicator Growth Media Vials Biological Indicator Test Envelopes Biological Indicator Test Envelopes

100 100

$338.95 $304.95 $732.95

100 $414.95

Universal Biological Indicator Incubator

1

25 12

$147.95

$74.95

BIOLOGICAL TEST PACKS • Fast, accurate monitoring of sterilization equipment - 48 hour lab turnaround time • Easy to use; place one test pack in sterilizer weekly (or more often, as desired) • Uses spore testing to dependably monitor sterilization • Complete system is ready to use: biological indicators in test packs, pre-addresses postage-paid envelopes and report forms all included • Versatile system can monitor steam, dry heat or eO gas sterilizers • Permanent record of results is provided • Positive test results are quickly communicated to your facility via phone

Biological Indicator Test Strips Biological Indicator Test Strips

100 $153.95 500 $730.95

STERILIZATION INTEGRATORS • Black indicator clearly denotes sterilization pass/fail • Chemical indicator for monitoring steam sterilization processes - steam, time, temperature • For use with steam sterilizers operating in the 250°f-275°f temperature range • During sterilization, a black bar migrates along a paper wick through fail and PaSS areas indicating whether the sterilization conditions were met • PaSS result assures that conditions in the pack were suócient to kill even the most resistant forms of micro-organisms • Meets requirements for Class 5 indicators according to aaMi/iSO 11140-1:2005

DUO SPORE BIOLOGICAL INDICATOR TEST WITH CULTURE SERVICE • For weekly or daily sterilizer monitoring and load monitoring during sterilization • Culture service program processes results within 48 hours after arrival in lab • D-values and Survival/Kill performance data supplied with each unit are compliant with US Pharmacopeia requirements • Test envelope contains 2 test strips, 1 control strip in two color separated pouches • Biological indicator for use in steam, ethylene oxide or dry heat cycles • Suitable for sterilizers in all clinical and non-clinical settings

ITEM

DESCRIPTION

PK

$

ITEM

DESCRIPTION

PK

$

ITEM

DESCRIPTION

PK

$

C6-1001-10 C6-1001-25

C6-2005-00

C6-2690-92 C6-2690-93 C6-2690-94

Vapor Line Sterilization Integrator Vapor Line Sterilization Integrator

100 250

$24.95 $41.95

Biological Test Pack & Culture Service

10

$194.95

Biological Indicator Test & Culture Service Biological Indicator Test & Culture Service Biological Indicator Test & Culture Service

1 4

$28.95 $94.95 $257.95

12

Fax: 800-671-7988 Tel: 800-237-5481 Order Online: www.bay-medical.com

153

Order Online: www.bay-medical.com Tel: 800-237-5481 Fax: 800-671-7988

152

Made with FlippingBook - Online Brochure Maker