LMA UNIQUE™ • Used on over 200 million patients worldwide • Simple, easy insertion • Minimally invasive airway • Reliable, proven performance with millions of safe uses • Proven ventilation in rescue situations
AURA-FLEX™ REINFORCED AIRWAY • Kink-free wire-reinforced tube eliminates risk of airway tube occlusion • High flexibility enables positioning away from the surgical field without loss of seal • Integrated pilot tube reduces risk of cutting pilot tube during surgery • Maximum intracuff pressure 60 cm H 2 0 for all sizes
ITEM DESCRIPTION SIZE
WEIGHT MAX CUFF VOLUME PK
$
ITEM DESCRIPTION SIZE WEIGHT
PK
$
1-2280-01 1-2280-15 1-2280-02 1-2280-25 1-2280-03 1-2280-04 1-2280-05
1-2270-02 1-2270-25 1-2270-03 1-2270-04 1-2270-05 1-2270-06
Neonate/Infant
1
up to 5kg 5kg - 10kg 10kg - 20kg 20kg - 30kg 30kg - 50kg 50kg - 70kg 70kg and over
4ml 7ml
10 $235.95 10 $235.95 10 $235.95 10 $235.95 10 $235.95 10 $235.95 10 $235.95
Pediatric Pediatric
2
10kg - 20kg 20kg - 30kg 30kg - 50kg 50kg - 70kg 70kg - 100kg
10ml 14ml 20ml 30ml 40ml 50ml
10 $237.95 10 $237.95 10 $237.95 10 $237.95 10 $237.95 10 $237.95
Infant
1.5
2.5
Pediatric Pediatric Pediatric
2
10ml 14ml 20ml 30ml 40ml
Adult Adult Adult Adult
3 4 5 6
2.5
3 4 5
100kg +
Adult Adult
• The only laryngeal mask included in the American Heart Association Guidelines 2010 for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care
GASTRO-LARYNGEAL TUBE (G-LT) • The ultimate two channel solution: One for securing the airway, and one for endoscopy • Offers greater stability of the sedation or anesthesia plan and reduction in cardio circulatory instability • Allows for faster endoscopic procedures and fewer interruptions due to intolerance or agitation • Extraglottic tube with ventilation and endoscopy lumen for control of Airway patency during gastrointestinal endoscopic procedures • Autoclavable up to 273° F
Proximal Cuff stabilizes the tube and blocks oro- and naso-pharynx
Ventilation Lumen with 15 mm ISO connector
Ventilation holes lie in front of the larynx
LMA SUPREME™ • Integrated drain tube designed to channel fluid and gas safely away from airway • Reliable, proven performance • Simple, easy insertion thanks to curved design • Can be used everywhere you use a mask and in places where you have been using an ET tube • Because of ease of insertion and reduced trauma, LMA™ airways have replaced ET tubes in many procedures
ITEM
DESCRIPTION Neonate up to 5kg
SIZE
MAX CUFF PK
$
Endoscopy Lumen fits duodenoscopes with maximum 13.8 mm O.D.
1-2281-01 1-2281-02 1-2281-03 1-2281-04 1-2281-05
1 2 3 4 5
4ml
1 1 1 1 1
$36.95 $36.95 $36.95 $36.95 $36.95
Infant/Child 10kg - 20kg Children 30kg - 50kg
10ml 20ml 30ml 40ml
Distal Cuff blocks esophageal inlet and reduces possibility of gastric ventilation
Adults 50kg - 70kg
ITEM DESCRIPTION
SIZE
PK $
1-2271-05
Gastro-Laryngeal Tube Adult ≥ 155cm 1 $318.95