BayMedical_Vol43_Issue1

Laryngeal Airways Disposable

Reinforced, Specialty Laryngeal Airways

A I RWAY MANAG EMENT

A I RWAY MANAG EMENT

MAX CUFF VOLUME

LMA UNIQUE™ • Used on over 200 million patients worldwide • Simple, easy insertion • Minimally invasive airway • Reliable, proven performance with millions of safe uses • Proven ventilation in rescue situations

AURA-FLEX™ REINFORCED AIRWAY • Kink-free wire-reinforced tube eliminates risk of airway tube occlusion • High flexibility enables positioning away from the surgical field without loss of seal • Integrated pilot tube reduces risk of cutting pilot tube during surgery • Maximum intracuff pressure 60 cm H 2 0 for all sizes

ITEM DESCRIPTION SIZE

WEIGHT MAX CUFF VOLUME PK

$

ITEM DESCRIPTION SIZE WEIGHT

PK

$

1-2280-01 1-2280-15 1-2280-02 1-2280-25 1-2280-03 1-2280-04 1-2280-05

1-2270-02 1-2270-25 1-2270-03 1-2270-04 1-2270-05 1-2270-06

Neonate/Infant

1

up to 5kg 5kg - 10kg 10kg - 20kg 20kg - 30kg 30kg - 50kg 50kg - 70kg 70kg and over

4ml 7ml

10 $235.95 10 $235.95 10 $235.95 10 $235.95 10 $235.95 10 $235.95 10 $235.95

Pediatric Pediatric

2

10kg - 20kg 20kg - 30kg 30kg - 50kg 50kg - 70kg 70kg - 100kg

10ml 14ml 20ml 30ml 40ml 50ml

10 $237.95 10 $237.95 10 $237.95 10 $237.95 10 $237.95 10 $237.95

Infant

1.5

2.5

Pediatric Pediatric Pediatric

2

10ml 14ml 20ml 30ml 40ml

Adult Adult Adult Adult

3 4 5 6

2.5

3 4 5

100kg +

Adult Adult

• The only laryngeal mask included in the American Heart Association Guidelines 2010 for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care

GASTRO-LARYNGEAL TUBE (G-LT) • The ultimate two channel solution: One for securing the airway, and one for endoscopy • Offers greater stability of the sedation or anesthesia plan and reduction in cardio circulatory instability • Allows for faster endoscopic procedures and fewer interruptions due to intolerance or agitation • Extraglottic tube with ventilation and endoscopy lumen for control of Airway patency during gastrointestinal endoscopic procedures • Autoclavable up to 273° F

Proximal Cuff stabilizes the tube and blocks oro- and naso-pharynx

Ventilation Lumen with 15 mm ISO connector

Ventilation holes lie in front of the larynx

LMA SUPREME™ • Integrated drain tube designed to channel fluid and gas safely away from airway • Reliable, proven performance • Simple, easy insertion thanks to curved design • Can be used everywhere you use a mask and in places where you have been using an ET tube • Because of ease of insertion and reduced trauma, LMA™ airways have replaced ET tubes in many procedures

ITEM

DESCRIPTION Neonate up to 5kg

SIZE

MAX CUFF PK

$

Endoscopy Lumen fits duodenoscopes with maximum 13.8 mm O.D.

1-2281-01 1-2281-02 1-2281-03 1-2281-04 1-2281-05

1 2 3 4 5

4ml

1 1 1 1 1

$36.95 $36.95 $36.95 $36.95 $36.95

Infant/Child 10kg - 20kg Children 30kg - 50kg

10ml 20ml 30ml 40ml

Distal Cuff blocks esophageal inlet and reduces possibility of gastric ventilation

Adults 50kg - 70kg

ITEM DESCRIPTION

SIZE

PK $

1-2271-05

Gastro-Laryngeal Tube Adult ≥ 155cm 1 $318.95

Adults 70-100kg and over

Fax: 800-671-7988 Tel: 800-237-5481 Order Online: www.bay-medical.com

61

Order Online: www.bay-medical.com Tel: 800-237-5481 Fax: 800-671-7988

60

Made with FlippingBook - Online Brochure Maker