LOAD CENTERS, ASSOCIATED CIRCUIT BREAKERS, AND ACCESSORIES, BUYLOG SECTION 1
1-24
— PowerMark Gold meter socket load centers
Single main, ring type, side-by-side, main breaker Main ampere rating 1 pole, 1” spaces 2 pole, 1” spaces 1 pole, 1/2” spaces 2 pole, 1/2” spaces Total 1-pole spaces
Interrupting current rating (kAIC) Front type
Bypass type
UL incoming Ordering code OH/UG TSM1610CFCU 1,4 OH/UG TSM1212CFCU 1 OH/UG TSM1612CFCU 1 OH/UG TSM2020CFCU 1,4
Max single pole circuits
100
16
8
32
14
32
32
22 Semi-flush
None
125
12 16 20
6 8
24 32 40
12 14 18
24 32 40
34 32 40
22 Semi-flush 22 Semi-flush 22 Semi-flush
None None None
200
10
100
16
8
32
14
32
32
22
Surface None
OH/UG TSM1610CSCU 1,2,3,4
125
12 16 20
6 8
24 32 40
12 14 18
24 32 40
24 32 40
22 22 22
Surface None Surface None Surface None
OH/UG TSM1212CSCU 1,2,3 OH/UG TSM1612CSCU 1,2,3 OH/UG TSM2020CSCU 1,2,3,4
— TSM1610CSCU
200
10
1 Accepts field installed fifth jaw terminal in the 3 or 9 o’clock position. Ordering code TJAW53; order separately. 2 Devices include removable closing cap. Order hub separately. See page 1-58. 3 Surface mounted units have two hub provisions on top end wall. 4 Unit ships with factory-installed solar-ready label.
Application data
Unit width (In inches)
Unit height (In inches)
Depth (In inches)
Factory inst. svcs disc
Main wire size (AWG/kcmil) Cu-Al
Equipment ground kit TGK12 (order separately) TGK12 (order separately) TGK12 (order separately) TGK12 (order separately) TGK12 (order separately) TGK12 (order separately) TGK12 (order separately) TGK12 (order separately)
Ordering code Box number
TSM1610CFCU TSM1212CFCU TSM1612CFCU TSM2020CFCU TSM1610CSCU TSM1212CSCU TSM1612CSCU TSM2020CSCU
R19 R19 R19 R17 R20 R20 R20 R18
14-3/4 14-3/4 14-3/4 16-3/4
28-1/2 28-1/2 28-1/2 34-1/4
7-5/16 7-5/16 7-5/16 7-5/16 5-7/16 5-7/16 5-7/16 6-5/16
THHQL THHQL THHQL THQMV THHQL THHQL THHQL THQMV
12-2/0 12-2/0 12-2/0 1-300 12-2/0 12-2/0 12-2/0 1-300
14-3/4 27-5/16 14-3/4 27-5/16 14-3/4 27-5/16
14-3/4
33
Single main, ring type, extra wide, main breaker Main ampere rating 1 pole, 1” spaces 2 pole, 1” spaces 1 pole, 1/2” spaces 2 pole, 1/2” spaces Total 1-pole spaces
Interrupting current rating
Bypass type
UL incoming Ordering code
Max single pole circuits
(kAIC) Front type
32 40
16 20
16
6 0
40 40
64 80
22 22
Surface None Surface None
UG UG
TSM3220UWCU 2 TSM4020UWCU 2
200
0
2 Devices include removable closing cap. Order hub separately. See page 1-58.
Application data
Unit width (In inches)
Unit height (In inches)
Depth (In inches)
Factory inst. svcs disc
Main wire size (AWG/kcmil) Cu-Al
Equipment ground kit TGK12 (order separately) TGK12 (order separately)
Ordering code Box number
TSM3220UWCU TSM4020UWCU
R28 R29
22-1/2 22-1/2
27-7/8 34-7/8
6-1/4 6-1/4
THQMV THQMV
1-300 1-300
NOTE: Circuit breakers must be ordered separately. Click here.