BuyLog Flippingbook JUN 2024

LOAD CENTERS, ASSOCIATED CIRCUIT BREAKERS, AND ACCESSORIES, BUYLOG SECTION 1

1-24

— PowerMark Gold meter socket load centers

Single main, ring type, side-by-side, main breaker Main ampere rating 1 pole, 1” spaces 2 pole, 1” spaces 1 pole, 1/2” spaces 2 pole, 1/2” spaces Total 1-pole spaces

Interrupting current rating (kAIC) Front type

Bypass type

UL incoming Ordering code OH/UG TSM1610CFCU 1,4 OH/UG TSM1212CFCU 1 OH/UG TSM1612CFCU 1 OH/UG TSM2020CFCU 1,4

Max single pole circuits

100

16

8

32

14

32

32

22 Semi-flush

None

125

12 16 20

6 8

24 32 40

12 14 18

24 32 40

34 32 40

22 Semi-flush 22 Semi-flush 22 Semi-flush

None None None

200

10

100

16

8

32

14

32

32

22

Surface None

OH/UG TSM1610CSCU 1,2,3,4

125

12 16 20

6 8

24 32 40

12 14 18

24 32 40

24 32 40

22 22 22

Surface None Surface None Surface None

OH/UG TSM1212CSCU 1,2,3 OH/UG TSM1612CSCU 1,2,3 OH/UG TSM2020CSCU 1,2,3,4

— TSM1610CSCU

200

10

1 Accepts field installed fifth jaw terminal in the 3 or 9 o’clock position. Ordering code TJAW53; order separately. 2 Devices include removable closing cap. Order hub separately. See page 1-58. 3 Surface mounted units have two hub provisions on top end wall. 4 Unit ships with factory-installed solar-ready label.

Application data

Unit width (In inches)

Unit height (In inches)

Depth (In inches)

Factory inst. svcs disc

Main wire size (AWG/kcmil) Cu-Al

Equipment ground kit TGK12 (order separately) TGK12 (order separately) TGK12 (order separately) TGK12 (order separately) TGK12 (order separately) TGK12 (order separately) TGK12 (order separately) TGK12 (order separately)

Ordering code Box number

TSM1610CFCU TSM1212CFCU TSM1612CFCU TSM2020CFCU TSM1610CSCU TSM1212CSCU TSM1612CSCU TSM2020CSCU

R19 R19 R19 R17 R20 R20 R20 R18

14-3/4 14-3/4 14-3/4 16-3/4

28-1/2 28-1/2 28-1/2 34-1/4

7-5/16 7-5/16 7-5/16 7-5/16 5-7/16 5-7/16 5-7/16 6-5/16

THHQL THHQL THHQL THQMV THHQL THHQL THHQL THQMV

12-2/0 12-2/0 12-2/0 1-300 12-2/0 12-2/0 12-2/0 1-300

14-3/4 27-5/16 14-3/4 27-5/16 14-3/4 27-5/16

14-3/4

33

Single main, ring type, extra wide, main breaker Main ampere rating 1 pole, 1” spaces 2 pole, 1” spaces 1 pole, 1/2” spaces 2 pole, 1/2” spaces Total 1-pole spaces

Interrupting current rating

Bypass type

UL incoming Ordering code

Max single pole circuits

(kAIC) Front type

32 40

16 20

16

6 0

40 40

64 80

22 22

Surface None Surface None

UG UG

TSM3220UWCU 2 TSM4020UWCU 2

200

0

2 Devices include removable closing cap. Order hub separately. See page 1-58.

Application data

Unit width (In inches)

Unit height (In inches)

Depth (In inches)

Factory inst. svcs disc

Main wire size (AWG/kcmil) Cu-Al

Equipment ground kit TGK12 (order separately) TGK12 (order separately)

Ordering code Box number

TSM3220UWCU TSM4020UWCU

R28 R29

22-1/2 22-1/2

27-7/8 34-7/8

6-1/4 6-1/4

THQMV THQMV

1-300 1-300

NOTE: Circuit breakers must be ordered separately. Click here.

Made with FlippingBook Digital Publishing Software