BuyLog Flippingbook MAR 2024

LOAD CENTERS, ASSOCIATED CIRCUIT BREAKERS, AND ACCESSORIES, BUYLOG SECTION 1

1-13

— PowerMark Gold load centers

Main lug, factory installed, indoor (NEMA 1) enclosure, top/bottom feed 1 Main ampere rating 1 pole, 1” spaces 2 pole, 1” spaces 1 pole, 1/2” spaces 2 pole, 1/2” spaces Total 1-pole spaces Max single pole circuits

Main wire size (AWG/kcmil) Cu-Al

Box number

Equipment ground kit TGK4 (order separately) TGK4 (order separately) TGL1 (order separately)

Ordering code TL240SCU 2,9 TL270SCU 2,9 TL412C 2,3,9 TL412CT 2,3,4,9 TPL412C 2,3,4,9

Front type

40 70

2 2 4 4 4 4 6 6 6 6 6 6 8 8 8 8 8 8

1 1 2 2 2 2 3 3 3 3 3 3 4 4 4 4 4 4 6

4 4 8 8 8 8

1 1 3 3 3 3 4 4 4 4 4 4 8 8 8 8 8 8 8

4 4 8 8 8 8

4 4 8 8

Surface Surface

1A 1A 2A 2A

14-4

6-3

125

Combination Combination

1-2/0 1-2/0 1-2/0 1-2/0

TGL1 installed

8 Thermoplastic 8 Thermoplastic

2 2

TGL1 (order separately)

TGL1 installed TPL412CT 2,3,4,9

12 12 12 12 12 12 16 16 16 16 16 16 20

12 12 12 12 12 12 16 16 16 16 16 16 24 24 24 24 24 32 32 40 40 42 40 40 64 40 40 80 42 42

12 12 12 12 12 12 16 16 16 16 16 16 28 32 32 48 48 32 32 40 40 48 64 64 64 80 80 80 84 64

Flush Flush Flush

3A 3A 3A 3A 3A 3A 3A 3A 3A 3A 3A 3A 18

6-1 6-1 6-1 6-1 6-1 6-1 6-1 6-1 6-1 6-1 6-1 6-1

TGL2 (order separately) TGL2 (order separately)

TLM612FCU 5,9 TLM612FCUD 5,9

TGL2 installed TLM612FCUDG 5,9

Surface Surface Surface

TGL2 (order separately) TGL2 (order separately)

TLM612SCU 5,9 TLM612SCUD 5,9

TGL2 installed TLM612SCUDG 5,9

Flush Flush Flush

TGL2 (order separately) TGL2 (order separately)

TLM812FCU 5,9 TLM812FCUD 5,9

TGL2 (order separately) TLM812FCUDG 5,9

Surface Surface Surface

TGL2 (order separately) TGL2 (order separately)

TLM812SCU 5,9 TLM812SCUD 5,9

TGL2 installed TLM812SCUDG 5,9

14 16 16 24 24 16 16 20 20 24 32 32 32 40 40 40 42 32

Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination Combination

6-2/0

Included 10

TLM1212CCU 8,9 TLM1612CCU 6

8 8

16 16

6 6 0 0

4 4 7 7 7 7 8 8

6-2/0 TGK12 or TGK24 (order separately)

6-2/0

TGK12 and TLK20 installed TLM1612CCUG 6

12 12

0 0

6-2/0 TGK24 or TGK32 (order separately)

TLM2412CCU 6

6-2/0 6-250 6-250 6-250 6-250

TGK24 and TLK20 installed TLM2412CCUG 6

200

8 8

32 32 40 40 36

14 14 18 18 18

TGK32 (order separately)

TLM1620CCU 7

TGK32 installed TLM1620CCUG 7

10 10 12

TGK32 (order separately)

TLM2020CCU 7

TGK42 installed TLM2020CCUG 7

9 1-3/0 (Cu), 2/0-3/0 (Al) 11 1-250 (Cu), 2/0-250 (Al)

TGK24 or TGK32 (order separately)

TLM2420C42 7

16

20

8

TGK32 and TLK20 (order separately) TGK32 (order separately)

TLM3220C42 7

16 16 16 20 20 20 20

16 16 64

6 6

11 11 19 13 13 20

6-250 6-300

TLM3220CCU 7

TGK32 and TNLK250 installed TLM3220CCUG 7

30

6-250 (2) TGK32 and (1) TLK250 installed TLM3220C64G 3

0 0

0 0

6-250 6-300

TGK42 (order separately)

TLM4020CCU 7

TGK42 and TNLK250 installed TLM4020CCUG 7

80

38

6-250 (2) TGK32 and (1) TLK250 installed TLM4020C80G2 7

0

0

14 1-300 (Cu), 2/0-300 (Al) 14 1-300 (Cu), 2/0-300 (Al) 14 1-300 (Cu), 2/0-300 (Al) 14 1-300 (Cu), 2/0-300 (Al)

TGK42 (order separately)

TLM4220CCU 7

42

20

0

0

42

84

Combination

TGK42 and TNLK250 installed TLM4220CCUG 7

225

42

20

0

0

42

84

Combination

TGK42 (order separately)

TLM4222CCU 7

42

20

0

0

42

84

Combination

TGK42 and TNLK250 installed TLM4222CCUG 7

1 TLM indicates units are convertible to main breaker. 2 No door 3 10 kAIC 4 125 amp maximum branch capacity. 5 For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. See page 1-59, 100 amp max. 6 For main breaker, order TQMH000. See page 1-48. Also order 2-pole THQL, THHQL, or TXQL circuit breaker. See page 1-43. 7 For main breaker, order THQMVXXXE circuit breaker from page 1-48.

8 For main breaker applications, use reverse feed THQL breaker or THHQL circuit breaker (see page 1-43) and THQLRK3 breaker retainer (see page 1-59). 9 No lock provision available. Use next size larger load center such as TLM1612CCU with a TDL106 accessory if locking provision is required. 10 Minimum order QTY is 40 for below 24 circuits; QTY 24 for 24 circuits and above. (See DEE-590) 11 Load center includes a factory installed ground bar and add-a-lug. A separate TGL2 can be added in the unlikey event that another ground bar is required.

NOTE: Circuit breakers must be ordered separately. Click here.

Made with FlippingBook Ebook Creator