BuyLog Flippingbook MAR 2024

MOLDED CASE CIRCUIT BREAKERS, BUYLOG SECTION 6

6-28

— Q-Line Circuit Breakers Plug-in Circuit Breakers 240V Class

THQL and THHQL 120/240 Vac, Ground Fault with Self-Test Feature # of Poles Ampere Rating Wire Range 1 120/240 Vac Interrupting Rating

Product Number THQL1115GFT THQL1120GFT THQL1125GFT THQL1130GFT THQL2115GFT THQL2120GFT THQL2125GFT THQL2130GFT THQL2135GFT2 THQL2140GFT2 THQL2145GFT2 THQL2150GFT2 THQL2160GFT2 THHQL1115GFT THHQL1120GFT THHQL1125GFT THHQL1130GFT THHQL2115GFT THHQL2120GFT THHQL2125GFT THHQL2130GFT

1 1 1 1 2 2 2 2 2 2 2 2 2 1 1 1 1 2 2 2 2

15 20 25 30 15 20 25 30 35 40 45 50 60 15 20 25 30 15 20 25 30

14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 8-3 Cu/8-3 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al

10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 10kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA 22kA

THQL1120GFT

THQL and THHQL 120 Vac, Equipment Protection Ground Fault Circuit Breakers Internal Common Trip # of Poles Ampere Rating Wire Range 1 120 Vac Interrupting Rating

THQL1120GFEP

Product Number THQL1115GFEP THQL1120GFEP THQL1130GFEP

1 1 1

15 20 30

14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al

10kA 10kA 10kA

THQL and THHQL 120/240 Vac or 208Y/120 Vac, Equipment Protection Ground Fault Circuit Breakers

120/240 Vac or 208Y/120 Interrupting Rating

# of Poles Ampere Rating Wire Range 1

Product Number

2 2 2 2 2

15 20 30 15 20

14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al

10kA 10kA 10kA 22kA 22kA

THQL2115GFEP THQL2120GFEP THQL2130GFEP THHQL2115GFEP THHQL2120GFEP

THQL2115GFEP

THQL and THHQL 120/240 Vac, High Intensity Discharge Lighting Loads # of Poles Ampere Rating Wire Range 1 120/240 Vac Interrupting Rating

Product Number THQL1115HID 2 THQL1120HID 2 THQL1125HID THQL1130HID THHQL1115HID 2 THHQL1120HID 2 THHQL1125HID THHQL1130HID Product Number THQL2115HID THQL2120HID THQL2125HID THQL2130HID THHQL2115HID THHQL2120HID THHQL2125HID THHQL2130HID

1 1 1 1 1 1 1 1

15 20 25 30 15 20 25 30

14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al

10kA 10kA 10kA 10kA 22kA 22kA 22kA 22kA

UL listed as HID.

THQL2120HID

THQL and THHQL 120/240 Vac, High Intensity Discharge Lighting Loads # of Poles Ampere Rating Wire Range 1 120/240 Vac Interrupting Rating

2 2 2 2 2 2 2 2

15 20 25 30 15 20 25 30

14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al 14-8 Cu/12-8 Al

10kA 10kA 10kA 10kA 22kA 22kA 22kA 22kA

UL listed as HID. 1 Solid or stranded for 14-10 AWG. 2 UL listed as SWD (switching duty). Suitable for 120 Vac fluorescent lighting loads.

Made with FlippingBook Ebook Creator