— ReliaMod™ Main fusible switch modules
ReliaMod™ main fusible switch modules include a UL489 molded case switch for on/off function and provisions for Class T fuses for overcurrent protection. Class T fuses are not included and are to be provided and installed by others.
Note: Please click on any specific ReliaMod™ ordering code with a hyperlink to be taken to the respective outline drawing/spec sheet for the product to view additional technical details.
Main fusible switch: 1-phase 3 wire 120/240Vac, lugs included, Class T fuses not included, order separately. Main ampere rating kAIC Fuse class Fusible switch frame Wire entry Incoming lug sizes per phase & neutral (AWG/kcmil Cu/Al) Service ground/ equipment ground (AWG/kcmil Cu/Al)
Ordering code
400 600 800
100 Class T Only
XT5-D Top/Bottom
(2) 2/0 - 500 (3) 2/0 - 400 (4) 4/0 - 500
(2) #6-350
RMM1F4R RMM1F6R RMM1F8R ¹
XT6-D XT7-D
Main fusible switch: 3-phase 4 wire 208Y/120Vac or 3-phase 4 wire 120/240Vac delta hi-leg, lugs included, Class T fuses not included order separately. Main ampere rating kAIC Fuse class Fusible switch frame Wire entry Incoming lug sizes per phase & neutral (AWG/kcmil Cu/Al) Service ground/ equipment ground (AWG/kcmil Cu/Al)
Ordering code
400 600 800
100 Class T Only
XT5-D Top/Bottom
(2) 2/0 - 500 (3) 2/0 - 400 (4) 4/0 - 500
(2) #6-350
RMM3F4R RMM3F6R RMM3F8R ¹
XT6-D XT7-D
— 600A MFS Module: RMM3F6R
EUSERC main fusible switch w/ pull box: 1-phase 3 wire 120/240Vac, Class T fuses not included, order separately Main ampere rating kAIC Fuse class Fusible switch frame Wire entry Incoming lug sizes per phase & neutral (AWG/kcmil Cu/Al) Service ground/ equipment ground (AWG/kcmil Cu/Al)
Ordering code
(2) #6-350 RMM1FE4RCLL ²
400
100 Class T Only
XT5-D
Bottom Lug landing pad accepts up to 1 wire landings per phase & neutral. Lugs not included, to be provided by others.
600
XT6-D
Lug landing pad accepts up to 2 wire landings per phase & neutral. Lugs not included, to be provided by others.
RMM1FE6RCLL ²
800
XT7-D
RMM1FE8RCLL ²
Note: These main fusible modules conform to EUSERC drawings 315, 345, and 347. However, for EUSERC applications please check with local utility requirements to make sure the pull box meets their specific dimensional requirements. Some specific EUSERC utilities or applications may require you to use a commercial metering switchboard or another type of solution other than these main breaker modules.
EUSERC main fusible switch w/ pull box: 3-phase 4 wire, 208Y/120Vac or 3-phase 4 wire 120/240Vac delta hi-leg, Class T fuses not included, order separately Main ampere rating kAIC Fuse class Fusible switch frame Wire entry Incoming lug sizes per phase & neutral (AWG/kcmil Cu/Al) Service ground/ equipment ground (AWG/kcmil Cu/Al)
Ordering code
— 800A MFS Module: RMM3FE8RCLL
(2) #6-350 RMM3FE4RCLL ²
400
100 Class T Only
XT5-D
Bottom Lug landing pad accepts up to 1 wire landings per phase & neutral. Lugs not included, to be provided by others.
600
XT6-D
Lug landing pad accepts up to 2 wire landings per phase & neutral. Lugs not included, to be provided by others.
RMM3FE6RCLL ²
800
XT7-D
RMM3FE8RCLL ²
Note: These main fusible modules conform to EUSERC drawings 315, 345, and 347. However, for EUSERC applications please check with local utility requirements to make sure the pull box meets their specific dimensional requirements. Some specific EUSERC utilities or applications may require you to use a commercial metering switchboard or another type of solution other than these main breaker modules. ¹ For larger 600-750 kcmil lugs on an XT7 frame main module, please order RXT7LUGKIT750. This kit will include mechanical lugs to accommodate (3) 500-750 kcmil Cu/Al cables per phase and neutral ²Lug landing pad only. Lugs not included, to be provided by others.