— ReliaMod™ Accessories
Surge protective device modules 1 (connects to meter center via included horizontal cross bus) Phase Voltage kA per Phase Enclosure Cross bus (amperage)
Ordering code RMM11SURGE RMM12SURGE RMM13SURGE 2 RMM31SURGE RMM32SURGE
1-Phase
120/240V
130 200 300 130 200 300
N3R Outdoor
1200
3-Phase
208Y/120V
RMM33SURGE 2 Note: For additional dimensions and technical data please click on the specific ReliaMod™ ordering code hyperlink in this catalog to view its respective outline drawings/spec sheet. These can also be found in ABB empower and the ABB Library. 1All SPD’s are UL1449 listed and come standard with LED Status indicators, audible alarm, and remote monitoring contacts. 2300kA per phase models also come with UL1283 EMI/RFI Noise Filtering & Surge Counter.
— RMM33SURGE
Surge protective device module dimensions Phase Voltage kA per Phase
W (in) 15.25 15.25 15.25 15.25 15.25 15.25
H (in) 25.14 25.14 25.14 25.14 25.14 25.14
D (in)
Ordering code RMM11SURGE RMM12SURGE RMM13SURGE RMM31SURGE RMM32SURGE
1-Phase
120/240V
130 200 300 130 200 300
12.7 10.0 10.0 12.7 10.0 10.0
3-Phase
208Y/120V
RMM33SURGE Note: For additional dimensions and technical data please click on the specific ReliaMod™ ordering code hyperlink in this catalog to view its respective outline drawings/spec sheet. These can also be found in ABB empower and the ABB Library.
— RMM33SURGE
Inside Corner Elbows
Inside corner elbow dimensions (in)
Enclosure Cross bus (amperage)
Ordering code RELBOW316N3R
Phase
Voltage
1-Phase or 3-Phase
120/240V or 208Y/120V
16 x 16 N3R Outdoor
1200
1-Phase or 3-Phase
120/240V or 208Y/120V
12 x 12
RELBOW312N3R
Note: For additional dimensions and technical data please click on the specific ReliaMod™ ordering code hyperlink in this catalog to view its respective outline drawings/spec sheet. These can also be found in ABB empower and the ABB Library.
— RELBOW316N3R
Spacer Phase
Voltage
Spacer width (in)
Enclosure Cross bus (amperage)
Ordering code
1-Phase or 3-Phase RSPACER3127 Note: Spacers can be useful for a variety of reasons. They can be installed between any two ReliaMod™ sections and will add an additional 7.25 inches of width between them. Some utilities require certain minimum widths between main modules and closest meter sockets which this spacer can help accomplish. Note: For additional dimensions and technical data please click on the specific ReliaMod™ ordering code hyperlink in this catalog to view its respective outline drawings/spec sheet. These can also be found in ABB empower and the ABB Library. 120/240V or 208Y/120V 7.25 N3R Outdoor 1200