LOAD CENTERS, METER COMBOS, SINGLE SOCKET METERING, AND RESIDENTIAL CIRCUIT BREAKERS, BUYLOG SECTION 1
1-21
— ReliaHome meter combos
Single main, ringless Main ampere rating
Max branch breaker spaces
Max branch breaker circuits
Interrupting
rating Front type Bypass type UL incoming
Ordering code TSMR1212CSCU 1 TSMB1212CSCU 1
125
12 12
24 24
22 22 22 22 22 22 22 22 22 22 22 22 22 22 22
Surface
Horn Bypass
OH/UG OH/UG
Surface Lever Bypass
150
4 4 4 8
8 8 8
Surface Surface Surface Surface Surface Surface Surface Surface Surface Surface
None None
OH/UG TSMR415CSCUGP 2,4 OH/UG TSMR415CSFLFMG 2,3
Horn Bypass
OH/UG
TSMR415CSCU
16 40 40
None
OH/UG TSMR815CSFLFMG 2,3
20 20
Horn Bypass
OH/UG OH/UG
TSMR2015CSCU 1 TSMB2015CSCU 1
Surface Lever Bypass
— TSMR420CSFL
200
4 4 4 8
8 8 8
None None
OH/UG TSMR420CSFLFMG 2,3 OH/UG TSMR420CSCUGP 2,4
Horn Bypass
OH/UG
TSMR420CSCU
16 40 40 40
None
OH/UG TSMR820CSFLFMG 2,3
20 20 20
Horn Bypass
OH/UG OH/UG
TSMR2020CSCU 1 TSMB2020CSCU 1
Surface Lever Bypass
Surface
None
OH/UG TSMR2020CSCUFMG 3
¹Devices include removable closing cap. Order hub separately. See page 1-57. ²Feed through lugs provided ³MEG Approved ⁴Georgia Power Approved
Application data
Enclosure depth (In inches)
Enclosure height (In inches)
Enclosure width (In inches)
Factory installed service disconnect
Main wire size (AWG/kcmil) Cu-Al
Box number
Equipment ground kit
Ordering code TSMR1212CSCU TSMB1212CSCU TSMR415CSCUGP TSMR415CSFLFMG TSMR815CSFLFMG TSMR2015CSCU TSMB2015CSCU TSMR420CSFLFMG TSMR420CSCUGP TSMR420CSCU TSMR2020CSCU TSMB2020CSCU TSMR820CSFLFMG TSMR415CSCU
R30 R20 R40
14-1/2 14-1/2 14-1/2 14-1/2 14-1/2 14-1/2 14-1/2 14-1/2 14-1/2 14-1/2 14-1/2 14-1/2 14-1/2 14-1/2 14-1/2
40-3/4 40-3/4
6-1/2 6-1/2 4-1/2 4-1/2 6-1/2 4-1/2 6-1/2 6-1/2 4-1/2 4-1/2 6-1/2 6-1/2 6-1/2 4-1/2 4-1/2
THHQL THHQL THQMV THQMV THQMV THQMV THQMV THQMV THQMV THQMV THQMV THQMV THQMV THQMV THQMV
6-350 TGK12 (Order separately) 12-2/0 TGK12 (Order separately)
32
6-350 6-350 6-350 6-350
TGL2 included TGL2 included TGK12 installed TGK24 included
R36A
28-1/2
R31
34 32
R37A
R30 R18
40-3/4 40-3/4 28-1/2
6-350 TGK12 (Order separately) 1-300 TGK12 (Order separately)
R36A
6-350 6-350 6-350
TGL2 included TGL2 included TGK12 installed
R40 R31 R30 R18
32 34
40-3/4 40-3/4
6-350 TGK12 (Order separately) 1-300 TGK12 (Order separately)
R37A
32
6-350 6-350
TGK24 included TGK24 included
TSMR2020CSCUFMG R403
34-1/2
NOTE: Circuit breakers must be ordered separately. Click here.