BuyLog Flippingbook NOV 2024
LOAD CENTERS, METER COMBOS, SINGLE SOCKET METERING, AND RESIDENTIAL CIRCUIT BREAKERS, BUYLOG SECTION 1
1-47
— ReliaHome circuit breaker accessories
ReliaHome P-Series/P-Series+ main breaker kit for use in 150A, 200A, & 225A convertible load centers - Example – PCCXX20 – 200A Convertible load center - Includes mounting base - Not for use in 125A and below Convertible load centers (PCCXX12) - Main Breaker Conversions for 125A load centers - see footnotes for individual ordering code numbers Description Ampere rating Ordering code
Lug size
Main circuit breaker kits 22,000 AIC
100 125 150 175 200 225
THQMV100F THQMV125F THQMV150F THQMV175F THQMV200F
1-300 (cu), 2/0-300
— THQMV100F with filler plates
THQMV225F Note: Wire bending rules affect allowed wire sizes when THQMV breakers are installed in an enclosure. For load centers, the wire range will be on the rating label. In addition, refer to the specifications for the main breaker versions of the load center you are considering to review allowed wire ranges when a PCCXX20 load center is converted to main breaker.
ReliaHome P-Series/P-Series+ main breaker kit For use with 125A P-series and P-series+ load Centers; 22kAIC RMS symmetrical Description Main Circuit Breaker Kit - Order appropriate THQL 10kAIC or THHQL 22kAIC breakers separately. Includes service barriers for use with THQL or THHQL main. TQMH000F¹ THQMH100F² THQMH125F³ Note: Please review the footnotes listed with the individual Load Center ordering codes for proper parts needed to convert to a main circuit breaker. This main breaker base is only applicable for all 125A ReliaHome convertible load centers. Ordering code
— THQMV200E
¹TQMH000F comes with the mounting base only and breaker must be ordered separately at desired amperage. ²THQMH100F comes with a factory installed 100A THHQL breaker. ³THQMH125F comes with a factory installed 125A THHQL breaker.
— TQMH000
ReliaHome T-Series and legacy PowerMark Gold and PRO main circuit breaker kit for use in 150A, 200A, & 225A convertible load centers - Example - TLMXX20CCU - 200A Convertible Load Center - Includes mounting base - Not for use in 125A and below Convertible Load Centers (TLMXX12CCU) - Main Breaker Conversions for 125A load centers - see footnotes for individual catalog numbers Description Ampere rating Ordering code Lug size Main circuit breaker kits 22,000 AIC 100 THQMV100E 1-300 (cu), 2/0-300 125 THQMV125E 150 THQMV150E 175 THQMV175E 200 THQMV200E 225 THQMV225E Note: Wire bending rules affect allowed wire sizes when THQMV breakers are installed in an enclosure. For load centers, the wire range will be on the rating label. In addition, refer to the specifications for the main breaker versions of the load center you are considering to review allowed wire ranges when a TLMXX20 load center is converted to main breaker. ReliaHome main circuit breaker kit For use with 125A ReliaHome T-Series and legacy PowerMark Gold and PRO load centers; 22kAIC RMS symmetrical. Description Ordering code Main Circuit Breaker Kit - Order appropriate THQL 10kAIC or THHQL 22kAIC breakers separately. Includes service barriers for use with THQL or THHQL main. TQMH000² ² Please review the footnotes listed with the individual Load Center ordering codes for proper parts needed to convert to a main circuit breaker. This main breaker base is only applicable for 16 circuit and larger 125 amp load centers, the TLM812RCU2, and all 125A ReliaHome convertible load centers.
Made with FlippingBook Ebook Creator