METERING, BUYLOG SECTION 2
2-13
— ReliaMod™ EUSERC main breaker modules
EUSERC main breaker: w/ pull box, 1-phase 3 wire 120/240Vac Main ampere rating kAIC Main breaker frame Breaker trip unit Wire entry
Service ground/ equipment ground (AWG/kcmil Cu/Al)
Incoming lug sizes per phase & neutral (AWG/kcmil Cu/Al) Landing pad has provisions for double hole lugs up to (1) 750 kcmil Cu/Al. Lugs not included, to be provided by others. Landing pad has provisions for double hole lugs up to (2) 750 kcmil Cu/Al. Lugs not included, to be provided by others. Landing pad has provisions for double hole lugs up to (3) 750 kcmil Cu/Al. Lugs not included, to be provided by others.
Ordering code RMM1BEL4R 1 RMM1BEH4R 1
(2) #6-350
400
65 XT5N 100 XT5S
TMA
Bottom
600
65 XT5N 100 XT5S 65 XT6N 100 XT6S 65 XT7S 100 XT7H 65 XT7S 100 XT7H
RMM1BEL6R 1 RMM1BEH6R 1 RMM1BEL8R 1 RMM1BEH8R 1 RMM1BEL10R 1 RMM1BEH10R 1 RMM1BEL12R 1,2
800
1000
Ekip Dip LS/I
1200
Ekip Touch LSI
RMM1BEH12R 1,2 Note: These main breaker modules conform to EUSERC drawings 315, 345, and 347. However, for EUSERC applications please check with local utility requirements to make sure the pull box meets their specific dimensional requirements. Some specific EUSERC utilities or applications may require you to use a commercial metering switchboard or another type of solution other than these main breaker modules. Note: Please click on any specific ReliaMod™ ordering code with a hyperlink to be taken to the respective outline drawing/spec sheet for the product to view additional technical details.
— 800A MCB Module: RMM3BEL8R
EUSERC main breaker: w/ pull box, 3-phase 4 wire 208Y/120Vac or 3-phase 4 wire 120/240Vac delta hi-leg Main ampere rating kAIC Main breaker frame Breaker trip unit Wire entry Incoming lug sizes per phase & neutral (AWG/kcmil Cu/Al) Service ground/ equipment ground (AWG/kcmil Cu/Al)
Ordering code RMM3BEL4R 1 RMM3BEH4R 1
(2) #6-350
400
65 XT5N 100 XT5S
TMA
Bottom
Landing pad has provisions for double hole lugs up to (1) 750 kcmil Cu/Al. Lugs not included, to be provided by others. Landing pad has provisions for double hole lugs up to (2) 750 kcmil Cu/Al. Lugs not included, to be provided by others. Landing pad has provisions for double hole lugs up to (3) 750 kcmil Cu/Al. Lugs not included, to be provided by others.
600
65 XT5N 100 XT5S 65 XT6N 100 XT6S 65 XT7S 100 XT7H 65 XT7S 100 XT7H
RMM3BEL6R 1 RMM3BEH6R 1 RMM3BEL8R 1 RMM3BEH8R 1 RMM3BEL10R 1 RMM3BEH10R 1 RMM3BEL12R 1,2
800
1000
Ekip Dip LS/I
1200
Ekip Touch LSI
RMM3BEH12R 1,2 Note: These main breaker modules conform to EUSERC drawings 315, 345, and 347. However, for EUSERC applications please check with local utility requirements to make sure the pull box meets their specific dimensional requirements. Some specific EUSERC utilities or applications may require you to use a commercial metering switchboard or another type of solution other than these main breaker modules. Note: Please click on any specific ReliaMod™ ordering code with a hyperlink to be taken to the respective outline drawing/spec sheet for the product to view additional technical details.
— 1200A MCB Module: RMM3BEL12R
1Lug landing pad only. Lugs not included, to be provided by others. 2RELT included