BuyLog Flippingbook OCT 2024 v2
LOAD CENTERS, METER COMBOS, SINGLE SOCKET METERING, AND RESIDENTIAL CIRCUIT BREAKERS, BUYLOG SECTION 1
1-15
— ReliaHome T-Series load centers
T-Series main lug convertible to main circuit breaker, NEMA 1 indoor
1 pole, 1” spaces
Max single pole circuits
Main wire size (AWG/kcmil) Cu-Al
Front type
Equipment ground kit TGL2 (order separately) TGL2 (order separately) TGL2 factory installed TGL2 (order separately) TGL2 (order separately) TGL2 factory installed TGL2 (order separately) TGL2 (order separately) TGL2 factory installed TGL2 (order separately) TGL2 (order separately) TGL2 factory installed TGL2 factory installed
Ordering code TLMQ612FCU ¹ , ² , ⁴ TLMQ612FCUD ¹ , ² TLMQ612FCUDG ¹ , ² TLMQ612SCU ¹ , ² , ⁴ TLMQ612SCUD ¹ , ² TLMQ612SCUDG ¹ , ² TLMQ812FCU ¹ , ² , ⁴ TLMQ812FCUD ¹ , ² TLMQ812FCUDG ¹ , ² TLMQ812SCU ¹ , ² , ⁴ TLMQ812SCUD ¹ , ² TLMQ812SCUDG ¹ , ² TLMQ1412CCU ² , ³
Main ampere rating
12
Flush Flush Flush
6-1 6-1 6-1 6-1 6-1 6-1 6-1 6-1 6-1 6-1 6-1 6-1
125
6
Surface Surface Surface
16
Flush Flush Flush
8
Surface Surface Surface
28
Combination
6-2/0
14
T-Series main lug convertible to main circuit breaker, NEMA 1 indoor white
1 pole, 1” spaces
Max single pole circuits
Main wire size (AWG/kcmil) Cu-Al
Front type
Equipment ground kit
Ordering code
Main ampere rating
28
Combination
6-2/0
Included³
TLMQ1412CCUW ² , ³
14
125
T-Series main lug convertible to main circuit breaker, NEMA 3R outdoor
1 pole, 1” spaces
Max single pole circuits
Main wire size (AWG/kcmil) Cu-Al
Front type
Equipment ground kit TGL2 (order separately) TGL2 (order separately) TGL2 factory installed
Ordering code TLMQ612RCU ¹ TLMQ812RCU ¹ TLMQ1412RCU ² , ³
Main ampere rating
12 16 28
– – –
6-1 6-1
125
6 8
6-2/0
14
¹For main breaker, order THQLRK2 retainer kit plus 2-pole circuit breaker. 100 amp maximum due to wire bending requirements. ²No lock provision available. Use next size larger load center such as PAL1612 with a TDL106 accessory if locking provision is required. ³For main breaker, order THQLRK3 retainer kit plus 2-pole circuit breaker. 100 amp maximum due to wire bending requirements. ⁴ Load center front does not come with door. If a door is desired choose the ordering code with D suffix. If a door and a factory installed ground bar is desired choose the ordering code with a DG suffix.
Made with FlippingBook - professional solution for displaying marketing and sales documents online