BuyLog Flippingbook OCT 2024 v2

RV POWER PEDESTALS AND INLETS, BUYLOG SECTION 3

3-5

— Ordering tables

Unmetered surface mount

Ground fault circuit breaker

Wire range table 1

Ordering code

Volts

Receptacles 30A/20A GFCI 50A/20A GFCI

Circuit protection THQL1130, THQL1120 THQL2150, THQL1120 THQL2150, THQL1130, THQL1120

Head type Lighted

Amps

100 120/240

N/A Single Side N/A Single Side

No No

1 GE1LU032SS 2 GE1LU502SS

70

120/240

100 120/240 50A/30A/20A GFCI

N/A Single Side

No

3 GE1LU532SS

— Unmetered surface mount

Ring type metered surface mount

Ground fault circuit breaker

Wire range table 1

Ordering code

Volts

Receptacles 30A/20A GFCI 50A/20A GFCI

Circuit protection THQL1130, THQL1120 THQL2150, THQL1120 THQL2150, THQL1130, THQL1120

Head type Lighted

Amps

100 120/240

N/A Single Side N/A Single Side N/A Single Side

No No No

2 GE1LM032SS 2 GE1LM502SS 4 GE1LM532SS

70

120/240

100 120/240 50A/30A/20A GFCI

Unmetered pad mount post

Ground fault circuit breaker

Wire range table 1

Ordering code

Volts

Receptacles

Circuit protection

Head type Lighted

Amps

100 120/240 50A/30A/20A GFCI

THQL2150, THQL1130, THQL1120 THQL2150, THQL1130, THQL1120 THQL2150, THQL1130, THQL1120

N/A Back-to-Back

No

5 GE1LU532PB

100 120/240 50A/30A/20A GFCI

N/A Single Side

No

6 GE1LU532PS

100 120/240 50A/30A/20A GFCI

N/A Single Side

Yes

6 GE1LU532PSL

Ring type metered pad mount post

Ground fault circuit breaker

Wire range table 1

Ordering code

Volts

Receptacles

Circuit protection

Head type Lighted

Amps

100 120/240 50A/30A/20A GFCI

THQL2150, THQL1130, THQL1120

N/A Single Side

No

7 GE1LM532PS

— Ring type metered pad mount post

Unmetered earth burial post

Ground fault circuit breaker

Wire range table 1

Ordering code

Volts

Receptacles 30A/20A GFCI 30A/20A GFCI

Circuit protection THQL1130, THQL1120 THQL1130, THQL1120 THQL2150, THQL1130, THQL1120 THQL2150, THQL1130, THQL1120 THQL2150, THQL1130, THQL1120GFT THQL2150, THQL1130, THQL1120 Circuit protection THQL1130, THQL1120 THQL2150, THQL1130, THQL1120 THQL2150, THQL1130, THQL1120 THQL2150, THQL1130, THQL1120GFT THQL2150, THQL1130, THQL1120

Head type Lighted

Amps

70 70

120/240 120/240

N/A Single Side N/A Single Side N/A Back-to-Back

No

6 GE1LU032ES 6 GE1LU032ESL 5 GE1LU532EB

Yes

100 120/240 50A/30A/20A GFCI

No

100 120/240 50A/30A/20A GFCI

N/A Single Side

No

6 GE1LU532ES

100 120/240

50A/30A/20A

20A

Single Side

No

6 GE1LU532ESG

100 120/240 50A/30A/20A GFCI

N/A Single Side

Yes

6 GE1LU532ESL

Ring type metered earth burial post

Ground fault circuit breaker

Wire range

Volts

Receptacles 30A/20A GFCI

Head type Lighted

table Ordering code

Amps

100 120/240

N/A Single Side N/A Back-to-Back

No No

7 GE1LM032ES 8 GE1LM532EB

100 120/240 50A/30A/20A GFCI

100 120/240 50A/30A/20A GFCI

N/A Single Side

No

7 GE1LM532ES

100 120/240

50A/30A/20A

20A

Single Side

No

7 GE1LM532ESG

100 120/240 50A/30A/20A GFCI

N/A Single Side

Yes

7 GE1LM532ESL

Made with FlippingBook - professional solution for displaying marketing and sales documents online