BuyLog Flippingbook OCT 2024 v2

SAFETY SWITCHES, BUYLOG SECTION 4

4-14

— Heavy duty safety switches

NEMA types 1 and 3R - 240Vac - fusible

Ordering code

Auxiliary contact kits SPDT DPDT

NEMA Type 1 indoor

NEMA Type 3R outdoor

Ground kit

Standard fuse class

Class J fuse kit

Class T fuse kit

Class R fuse rejection kit 8

Amperage rating

Neutral kit

2 pole / 3 wire

TH3221 7 TH3222 1 , 7 TH3223 1 , 7

TH3221R 1 TH3222R 1 TH3223R 1 , 7 TH3224R 1 , 3 , 7

30 60

TGL1

Factory installed

H, K, and R

Move load– block

– – –

TRK12B THAUX61S THAUX21D

TRK22A TRK46A

– – – –

THAUX64D

N

N

100 200 400 600 800

TNG3

TH3224 1,2 , 3 , 7

THF3225A1 1,2 , 3 , 7 THF3226A1 1 , 2 , 3

THF3225AR 1 , 3 , 7 THF3226AR 1 , 3

TGL6

THT5A

TRK56A TRK66A

THAUX66D

N

N

N

N

THJ6 THT6A

TC72267 4 , 6 TC72268 4 , 6

TC72267R 4 , 6 TC72268R 4 , 6

5

TNI67

L

– –

– –

– –

– –

– –

1200 9

5

TNI68A

N

N

3 pole / 3 wire

THF3325A1 1 , 2 , 7

THF3325AR1 7

400

TGL6

TNI65 or TNI65A750

H, K, and R

Move load– block

– THAUX66DA

THT5A

TRK56A

THF3326A1 1 , 2

N

N

600

THF3326AR1

TNI66

THJ6 THT6A

TRK66A

3 pole / 4 wire

TH4321 1 TH4322 1 TH4323 1 , 7

TH4321R 1 TH4322R 1 TH4323R 1 , 7 TH4324R 1 , 3 , 7

30 60

TGL1

Factory installed

H, K, and R

Move load– block

– – –

TRK12B THAUX61S THAUX21D

TRK22A TRK46A

– – –

THAUX64D

N

N

100 200 400 600

TNG3

TH4324 1 , 2 , 3 , 7

THF4325A1 1,2 , 3 , 7 THF4326A1 1,2 , 3

THF4325AR 1 , 3 , 7 THF4326AR 1 , 3

TGL6

THT5A

TRK56A TRK66A

– THAUX66DA

N

N

THJ6 THT6A

N

N

NEMA types 1 and 3R - 240Vac -non-fusible

Ordering code

Auxiliary contact kits SPDT DPDT

NEMA Type 1 indoor

NEMA Type 3R outdoor

Ground kit

Standard fuse class

Class J fuse kit

Class T fuse kit

Class R fuse rejection kit 8

Amperage rating

Neutral kit

3 pole / 3 wire / 240Vac

30

THN3321

TGL1

TNI21

THAUX61S THAUX21D

1 Available with viewing window, add "VW" suffix. 2 Type 1 enclosure: 200-600 ampere devices available factory reversed for bottom feed. Add "B" suffix. Handle will be on the left side. For 400–600 ampere devices, add "BL" suffix. Handle will be on the left side. 3 For switches CSA Certified for service entrance, add "C" suffix. Will include solid neutral. For 400–600 A, add "CN" suffix. Will include solid neutral. 4 For switches suitable for service entrance applications in Canada, order TH3267C, TH3267C, TH3267RC, TH3268C, or TH3268RC. 5 Neutral kit is groundable and bondable. 6 Rated 600 Vac only. Accepts Class L fuses only. Type HD electrical performance does not apply. 7 Switches may be adapted to accept Class J fuses without a kit by moving the load-block toward the switch base and remounting. 8 When specifications permit only Class R fuses, these kits may be installed in the switch to deter fuses other than Class R from being installed. 9 May require additional provisions when 1200A fuses are used to meet NEC 240.67 2017 or later.

Made with FlippingBook - professional solution for displaying marketing and sales documents online