Control_Flippingbook_October 2023
1-55
NEMA FULL VOLTAGE POWER DEVICES, CONTROL SECTION 1
— CR487 mag-break magnetic starters Nonreversing, combination, mag-break circuit breaker type
Part number configuration Valid for NEMA sizes 0–4
Digits:
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16
17
C R
Steps:
Step 1
Step 2
Step 3
Step 4 Step 5 Step 6 Step 7 Step 8 Step 9
To configure the part number, use the tables below to fill in the digit boxes with the appropriate code.
— Step 1 (digits 1-7) select NEMA size and enclosure
NEMA type 1
NEMA type 3R
NEMA type 12
NEMA type 4/4X
Oversized enclosure CR
Standard enclosure CR
Oversized enclosure CR
Standard enclosure CR
Oversized enclosure CR
Standard enclosure CR
Oversized enclosure CR
Standard enclosure CR
NEMA size
0 1 2 3 4
Use CR387 Use CR387 Use CR387
487B5 487C5 487D5 487E5 487F5
487B6 487C6 487D6 487E6 487F6
487BR 487CR 487DR 487ER 487FR
487B2 487C2 487D2 487E2 487F2
487B7 487C7 487D7 487E7 487F7
487B4 487C4 487D4 487E4 487F4
487BS 487CS 487DS 487ES 487FS
487E1 487F1
Note: All enclosures include external overload reset buttons. NEMA 4 enclosures are stainless steel.
— Step 2 (digits 8, 9) select control voltage (extra capacity CPT + 100 VA and 200 VA)
— Step 2 (digits 8, 9) select control voltage (no CPT and standard size CPT)
Control fuses, no CPT
Standard size CPT
Standard size CPT + 100 VA
Standard size CPT + 200 VA
Control circuit voltage and CPT 120 V w/ surge protector (SP)
No CPT
Control circuit voltage and CPT 120 V w/ surge protector (SP)
01 02 03 04 05 08 09
F1 F2 F3 F4 F5 F8
– – – – – – –
– – – – – – –
– – – – – – –
120 V 240 V 480 V 600 V 208 V 24 V 1
120 V 240 V 480 V 600 V 208 V 24 V 1
– – – – – – – – – – – – –
240 V/120 V w/CPT 480 V/120 V w/CPT 600 V/120 V w/CPT 208 V/120 V w/CPT
– – – – – – – – – – – –
93 94 95 98 33 34 35 38 S3 S4 S5 S8
240 V/120 V w/CPT 480 V/120 V w/CPT 600 V/120 V w/CPT 208 V/120 V w/CPT
13 14 15 18 53 54 55 58 A3 A4 A5 A8
23 24 25 28 63 64 65 68 B3 B4 B5 B8
240 V/120 V w/CPT and SP 480 V/120 V w/CPT and SP 600 V/120 V w/CPT and SP 208 V/120 V w/CPT and SP
240 V/120 V w/CPT and SP 480 V/120 V w/CPT and SP 600 V/120 V w/CPT and SP 208 V/120 V w/CPT and SP
240 V/24 V w/CPT 1 480 V/24 V w/CPT 1 600 V/24 V w/CPT 1 208 V/24 V w/CPT 1
240 V/24 V w/CPT 1 480 V/24 V w/CPT 1 600 V/24 V w/CPT 1 208 V/24 V w/CPT 1
Note: CPT includes 2 primary fuses and 1 secondary fuse. 1 24 V coils not available for NEMA size 3 and 4. 2 Requires oversized enclosure for NEMA sizes 0-2. Select proper NEMA size and enclosure type from step 1 (digits 1-7) table, above.
1 24 V coils not available for NEMA size 3 and 4.
Made with FlippingBook Online newsletter creator