Low Voltage Power & Insulated Case Circuit Breakers Section 8

EntelliGuard ™ G Low Voltage Power Circuit Breakers EntelliGuard ™ G Cassettes Nomenclature

Digit 5—Cassette AIC Rating

Interrupting Rating Tier ANSI/UL1066 Devices, LVPCB Envelope 1 Envelope 2 Envelope 3 1/2S Override Code 254V 580V 635V Withstand HSIOC No. 1 Override WI Code 400-1200 400-2000 3200 400-3200 3200 4000-5000 S 65,000 65,000 50,000 50,000 50,000 49,000 53,500 S X N 65,000 65,000 65,000 65,000 None None None N X X H 85,000 85,000 65,000 65,000 65,000 63,700 69,500 H X P 2 100,000 100,000 65,000 65,000 65,000 63,700 69,500 P X E 85,000 85,000 85,000 85,000 None None None E X M 100,000 100,000 100,000 85,000 85,000 83,800 90,950 M X X B 100,000 100,000 100,000 100,000 None None None B X X L 150,000 150,000 100,000 100,000 100,000 98,000 107,000 L X X Interrupting Rating Tier UL489 Devices ICCB Envelope 1 Envelope 2 Envelope 3 1/2S Override Code 240V 480V 600V Withstand HSIOC No. 1 Override WI Code 400-1200 400-2000 2500-3000 400-3000 3000 4000-6000 M 100,000 100,000 100,000 65,000 65,000 N/A 69,550 M X X L 150,000 150,000 100,000 85,000 85,000 N/A 90,950 L X X P 2 100,000 100,000 65,000 50,000 50,000 N/A 50,000 P X ANSI Non-Automatic Switches 30 Cycle Withstand Ratings Envelope 1 Envelope 2 Envelope 3 Code 254V 580V 635V Code 800-2000 800-3000 3000-6000 N 42,000 42,000 42,000 N X M 65,000 65,000 65,000 M X B 100,000 100,000 100,000 B X UL489 Non-Automatic Switches Envelope 1 Envelope 2 Envelope 3 Code 240V 480V 600V Code 800-2000 800-3000 3000-6000 N 42,000 42,000 42,000 N X M 65,000 65,000 65,000 M X B 150,000 150,000 100,000 B X breaker set with maximum setting be employed using external control or protection as required by the application. Note: Non-automatic switches are provided with no internal sensing or tripping mechanism and cannot be applied above their respective withstand levels. If a non-automatic device is required at ratings above the available switches is required, it is recommended that a circuit S 65,000 65,000 50,000 42,000 42,000 N/A 44,940 S X N 65,000 65,000 65,000 42,000 42,000 N/A 44,940 N X X H 85,000 85,000 65,000 50,000 50,000 N/A 53,500 H X X

Digit 6 Number of Poles Devices Series/ Line Code OEM Cassette - 3 Pole 2 OEM Cassette - 4 Pole 5 GE Equipment Cassette - 3 Pole 1 7 1 GE Equipment cassette designed specifically for AKD20 Switchgear. These cassettes are NOT available for OEMs. 2 P frame available as 3-pole only Digit 7 Shutters Shutters with Locks Code Shutter and Shutter Lock - Factory Installed S None X Loose Cassette Parts- Field Installed Product Number Carriage Position Switch - 1NO/1NC GCPS1R Carriage Position Switch-2NO/2NC GCPS2R 1 Kirk Key Interlock Cam for Cassette GCKRKR 1 Ronis Key Interlock Cam for Cassette GCR0NR Secondary Disconnect Block B, 39 Pole-Top Mounted GSDWTR Secondary Disconnect Block B, 39 Pole-Side Mounted GSDWSR Secondary Disconnect Block B is required when: 1. Any "ZONE SELECTIVE INTERLOCKING" options are selected in breaker/trip unit Catalog Digit 18. 2. Any "ADVANCED FEATURES" are selected in breaker/trip unit Catalog Digit 19. 3. A COIL SIGNALING CONTACT OPTION is selected, Digit 12. 4. A READY TO CLOSE signal via the trip unit is selected, Digit 13. 5. Any of the following OPTIONAL Aux. Contact Switches are selected in Digit 12: —8NO/NC POWER RATED

—3NO/NC POWER RATED + 2NO/NC Hi-Fi —4NO/NC POWER RATED + 4NO/NC Hi-Fi

Rev. 1/19 Data subject to change without notice

GE Products BuyLog

go.abb/industrial

8-12

Made with FlippingBook - Online magazine maker