GE Products BuyLog Smart Catalog

Section 10

Dry Type Transformers General Purpose Copper Three-Phase DOE 2016 Efficiency

150°C Rise NEMA 2 Input

Output Voltage

Wiring

Approx. Net Weight (Lbs)

Frame

Product Number

Diagram No. 1

Voltage

kVA

Taps

Size

15 30 45 75

(+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -2 2.5%)

13 13 13 13 13 13 13 13 13

230 353 480 661 790

UX71C UX72C UX73C UY74C DY75C DY76C DY77C DY78C DX79C

9T10C1191 9T10C1192 9T10C1193 9T10C1194 9T10C1195 9T10C1196 9T10C1197 9T10C1198 9T10C1199

480 Volts Delta

240 Volts

112.5

150 225 300 500

1085 1610 1970 3720

150°C Rise NEMA 2 Input

Output Voltage

Wiring

Approx. Net Weight (Lbs)

Frame

Product Number

Diagram No. 1

Voltage

kVA

Taps

Size

15 30 45 75

(+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -2 2.5%)

12 12 12 12 12 12 12 12 12

230 353 480 661 790

UX71C UX72C UX73C UY74C DY75C DY76C DY77C DY78C DX79C

9T10C2401 9T10C2402 9T10C2403 9T10C2404 9T10C2405 9T10C2406 9T10C2407 9T10C2408 9T10C2409

600 Volts Delta

208Y/120 Volts

112.5

150 225 300 500

1085 1610 1970 3720

150°C Rise NEMA 2 Input

Output Voltage

Wiring

Approx. Net Weight (Lbs)

Frame

Product Number

Diagram No. 1

Voltage

kVA

Taps

Size

15 30 45 75

(+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -2 2.5%)

12 12 12 12 12 12 12 12 12

230 353 480 661 790

UX71C UX72C UX73C UY74C DY75C DY76C DY77C DY78C DX79C

9T10C1001 9T10C1002 9T10C1003 9T10C1004 9T10C1005 9T10C1006 9T10C1007 9T10C1008 9T10C1009

480 Volts Delta

208Y/120 Volts

112.5

150 225 300 500

1085 1610 1970 3720

115°C Rise NEMA 2 Input

Output Voltage

Wiring

Approx. Net Weight (Lbs)

Frame

Product Number

Diagram No. 1

Voltage

kVA

Taps

Size

15 30 45 75

(+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%)

12 12 12 12 12 12 12 12

230 353 480 748 900

UX71C UX72C UX73C UX74C DX75C DX76C DX77C DX78C

9T10C1001G31 9T10C1002G31 9T10C1003G31 9T10C1004G31 9T10C1005G31 9T10C1006G31 9T10C1007G31 9T10C1008G31

480 Volts Delta

208Y/120 Volts

112.5

150 225 300

1240 1847 2150

80°C Rise NEMA 2 Input

Output Voltage

Wiring

Approx. Net Weight (Lbs)

Frame

Product Number

Diagram No. 1

Voltage

kVA

Taps

Size

15 30 45 75

(+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -4 2.5%) (+2, -2 2.5%)

12 12 12 12 12 12 12 12

353 480 661 790

UX72C UX73C UY74C DY75C DY76C DY77C DX78C DX79C

9T10C1001G61 9T10C1002G61 9T10C1003G61 9T10C1004G61 9T10C1005G61 9T10C1006G61 9T10C1007G61 9T10C1008G61

480 Volts Delta

208Y/120 Volts

112.5

1085 1610 2150 3720

150 225 300

1 See page 10-45 for wiring diagrams.

Rev. 1/19 Data subject to change without notice

go.abb/industrial

GE Products BuyLog

10-11

Made with FlippingBook - Online magazine maker