GE Products BuyLog Smart Catalog
Panelboards Spectra ™ Series Panelboards Power Renewal Parts Type CCB and QMR Panelboards Order through the Customer Service Center unless stated otherwise below.
Section 11
QMR Fusible Switch 240V 1, 2 Switch Number
QMR Fusible Switch 600V 1, 2 Switch Number
Product Number
Product Number THFP361 THFP361L THFP362 THFP362L THFP363 THFP363L THFP364 THFP365 THFP366 THFP367 THFP368
Amps
of Poles
Description
Amps
of Poles
Description
30 30 60 60 60 60
3 3 3 3 3 3 3 3 3 3 3
Left Hand Unit
THFP321L THFP321X THFP322 THFP322L THFP322X THFP322XL THFP323 THFP323L THFP324 THFP325 THFP326
30 30 60 60
3 3 3 3 3 3 3 3 3 3 3
Right Hand Unit Left Hand Unit Right Hand Unit Left Hand Unit Right Hand Unit Left Hand Unit Center Mount Center Mount Center Mount Center Mount Center Mount
Right Hand Unit - 3X
Right Hand Unit Left Hand Unit
Right Hand Unit - 3X Left Hand Unit - 3X
100 100 200 400 600 800
100 100 200 400 600
Right Hand Unit Left Hand Unit Center Mount Center Mount Center Mount
1200
1 Limited availability. Obsolete when inventory depleted. 2 Switch and mounting hardware kit must be ordered separately
QMR Mounting Hardware Kits Are Copper for Use with Cu or Al Main Bus Dual Mounted
Maximum Horsepower Ratings QMR Fusible Switch
Vac Vdc Rating in 2-Pole 3-Pole 2-Pole 3-Pole Amperes 3 120 240 480 600 240 480 600 125 250 With Standard and Fuses (Class H) 30 1/2 1 1/2 3 3 3 5 7 1/2 2 5 60 1 1/2 3 5 10 7 1/2 15 15 5 10 100 — 7 1/2 10 15 15 25 30 — 20 200 — 15 25 30 25 50 60 — 40 400 — — — — 50 100 125 — — 600 — — — — 75 150 200 — — With “Time-delay” Fuses (Class H) 30 2 5 10 15 10 20 20 3 — 60 3 10 20 25 20 40 50 5 — 100 — 15 30 40 30 60 75 — — 200 — 30 50 50 60 125 150 — — 400 — — — — 125 250 350 — — 600 — — — — 200 400 500 — — 3 Ratings are based on latest revision of the National Electric Code Article 430. Horsepower ratings for switches with standard class H fuses are based on one-time fuses having minimum time-delay. When time-delay fuses are used the horsepower ratings are maximum for the switches. QMR Fusible Switch Terminations 4 Switch Wire Range Wires Lugs Amperes Voltage (Cu/Al) per Lug per Phase 30 250/600 #14-10 1 1 60 250/600 #14-2 1 1 100 250/600 #10-1/0 1 1 200 250/600 #6-250kcmil or 1 1 2(I/O-250kcmil) 400 250/600 #6-250kcmil or 1 1 2(I/O-250kcmil) 600 250/600 250-350kcmil Cu or 2 2 350-500kcmil Al 800 250/600 #4-600kcmil 1 4 1000 250/600 #4-600kcmil 1 4 4 For optional lugs refer to GEH-460B
Product Number
Breaker Frame
Kit Ampere Rating
Voltage
THFP THFP THFP THFP
30-60A
240 & 600V
THFP62DPK THFP63DPKJ THFP63DPK
100A 100A
600V
240 & 600V
100-30/60 THFP63DPKC Note: QMR Power Panelboards 600V, 100A double branch units require a minimum width of 40". 600V, 30A and 60A double branch, and 240V, 30A, 60A and 100A single and double branch units can be built in a 35" wide enclosure. 600V
QMR Mounting Hardware Kits Are Copper for Use with Cu or Al Main Bus Single Mounted
Product Number
Breaker Frame
Kit Ampere Rating
Voltage
THFP THFP THFP THFP THFP THFP THFP
30/60A
240V
THFP22SPK THFP62SPK THFP63SPK THFP64SPK THFP65SPK THFP66SPK
30/60/100A
240V & 600V
100A 200A 400A 600A
600V
240 & 600V 240 & 600V 240 & 600V 240 & 600V
1200A THFP67SPK Note: QMR Power Panelboards 600V, 100A double branch units require a minimum width of 40". 600V, 30A and 60A double branch, and 240V, 30A, 60A and 100A single and double branch units can be built in a 35" wide enclosure.
Rev. 1/19 Data subject to change without notice
GE Products BuyLog
go.abb/industrial
11-48
Made with FlippingBook - Online magazine maker