GE Products BuyLog Smart Catalog
Motor Control Centers—Low Voltage GE Fastrac Program—MCC Units Quick Selection Guide
Section 15
CR8000
5
5
Select Pilot Devices (continued)
Select Pilot Devices Select pilot devices desired by starter type. See Pilot Devices table below and note the lamp type as either Incandescent or LED. Transfer the product number digits to the boxes marked in the product number line. I 5
Incandescent Product Number Digits
LED Product Number Digits
Starter Type
Pilot Device
NONE - Blank Pilot Device Bracket Provided
NN
-
RED/AMBER LGT STD RED/AMBER LGT PTT R/A/G LGT STD R/A/G LGT PTT FAST/SLOW/STOP PB
EF ES EG ET EN EB EP EC EQ FN FB FP FC FQ
SF SS SG ST - SB SP SC SQ - TB TP TC TQ
Incandescent Product Number Digits
LED Product Number Digits
Starter Type
S
Pilot Device NONE - Blank Pilot Device Bracket Provided RED LGT STD RED LGT PUSH-TO-TEST (PTT) RED/GREEN LGT STD RED/GREEN LGT PTT HAND/OFF/AUTO (H/O/A) SW.
NN*
-
AE* AF AS* AT AN* AB* AP AC*
R
OE* OF OS* OT - OB* OP OC* OQ OD OR - PB* PP PC PQ - UB* UP UC* UQ
FAST/SLOW/STOP PB R/A LGT STD FAST/SLOW/STOP PB R/A LGT PTT FAST/SLOW/STOP PB R/A/G LGT STD FAST/SLOW/STOP PB R/A/G LGT PTT FAST/SLOW/OFF/AUTO (F/S/O/A) SW
2S1W & 2S2W
H/O/A SW. RED LGT STD H/O/A SW. RED LGT PTT H/O/A SW. R/G LGT STD H/O/A SW. R/G LGT PTT
F/S/O/A SW R/A LGT STD F/S/O/A SW R/A LGT PTT F/S/O/A SW R/A/G LGT STD F/S/O/A SW R/A/G LGT PTT
AQ AD AR
FVNR & RVAT & RVSS
H/O/A SW. STOP/START PB RED LGT STD H/O/A SW. STOP/START PB RED LGT PTT STOP/START PB
6
Select Overload Relay Select overload relay type. Transfer the product number digits to the box marked in the product number line. 6
BN* BB*
STOP/START PB RED LGT STD STOP/START PB RED LGT PTT STOP/START PB R/G LGT STD STOP/START PB R/G LGT PTT OFF/ON SW. OFF/ON SW. RED LGT STD OFF/ON SW. RED LGT PTT OFF/ON SW. R/G LGT STD OFF/ON SW. R/G LGT PTT NONE - Blank Pilot Device Bracket Provided
BP BC BQ
Relay Type
Product Number Digit
Standard
1
GN* GB* GP GC* GQ
Ambient Compensated
2* 3
Solid State
7
Select Control Terminal Board Select control disconnect terminal board. Transfer the product number digits to the box marked in the product number line. 7
NN
-
RED/GREEN LGT STD RED/GREEN LGT PTT RED/AMBER LGT STD RED/AMBER LGT PTT R/A/G LGT STD R/A/G LGT PTT FWD/REV/STOP PB
CE CR CF CS CG CT CN CB CP CC CQ DN DB DP DC DQ
QE QR QF QS QG QT - QB QP QC QQ - RB RP RC RQ
Control Disconnect Terminal Board
Product Number Digit
Standard High-Density
H
8
Select Horsepower Select horsepower. Transfer the product number digits to the boxes marked in the product number line. Note that some product number digits consist of a decimal point. 8
FWD/REV/STOP PB R/A LGT STD FWD/REV/STOP PB R/A LGT PTT FWD/REV/STOP PB R/G/A LGT STD FWD/REV/STOP PB R/G/A LGT PTT FWD/OFF/REV SW FWD/OFF/REV SW RED LGT STD FWD/OFF/REV SW RED LGT PTT FWD/OFF/REV SW R/G LGT STD FWD/OFF/REV SW R/G LGT PTT
FVR
Horsepower
Product Number Digits
Horsepower
Product Number Digits
1/4
.25
15
015
1/3
.33
20
020
3/8
.38
25
025
1/2
.50
30
030
3/4
.75
40
040
1
001
50
050
1 1/2
1.5
60
060
2
002
75
075
3
003
100
100
5
005
125
125
7 1/2
7.5
150
150
10
010
200
200
Note: Contact Factory for pricing.
Rev. 1/19 Data subject to change without notice
GE Products BuyLog
go.abb/industrial
15-16
Made with FlippingBook - Online magazine maker