Haier - hOn
Page 4 of 7
Report No.: AHEE230300050751
Test protocol to measure the fractional energy saving
Test Details Description – Cooling mode Model
AS12FBAHRA(indoor unit) + 1U12MEHFRA(outdoor unit)
Test voltage(V)/ Test frequency(Hz)
230 V, 50 Hz
EN14511-2: 2022/ Table 4: Cooling Mode – Standard Rating Conditions; Indoor Room Size: 22.34 mm 2 ; Installation Height of Indoor Unit: 2.3 m; Indoor Room Dry Bulb( ℃ )/Wet Bulb( ℃ ) : 27/19; Outdoor Room Dry Bulb( ℃ )/Wet Bulb( ℃ ) : 35/24
Test conditions
Measurement 1 Settings
Air conditioner is set to cooling mode, the temperature is set to 16 ℃ , the wind speed is set to min.
Test method
After the indoor side test room and walls reaching the setting temperature, the appliance is then operated continually for 5 hours, and record the values of power consumption per hour
Test data
Details see below table
Measurement 2 Settings
Air conditioner is set to cooling mode, the temperature is set to 16 ℃ , the wind speed is set to max.
Test method
After the indoor side test room and walls reaching the setting temperature, the appliance is then operated continually for 5 hours, and record the values of power consumption per hour.
Test data
Details see below table
Measurement 3 Settings
Air conditioner is set to cooling mode, the temperature is set to 26 ℃ , the wind speed is set to max.
Test method
After the indoor side test room and walls reaching the setting temperature, the appliance is then operated continually for 5 hours, and record the values of power consumption per hour.
Test data
Details see below table
Measurement 4 Settings
Air conditioner is set to cooling mode, the temperature is set to 26 ℃ , the wind speed is set to min.
Test method
After the indoor side test room and walls reaching the setting temperature, the appliance is then operated continually for 5 hours, and record the values of power consumption per hour.
Test data
Details see below table
Set to ‘ Cooling-26 ℃ - min wind ’ speed mode compared to 16 ℃ , can save the energy consumption 0.316 kwh per hour, the ration of fractional energy saving can up to 63%. Set to ‘ Cooling-26 ℃ - max wind speed ’ mode compared to 16 ℃ , can save the energy consumption 0.591 kwh per hour, the ration of fractional energy saving can up to 88%.
Comparison of measurement 1&4
Conclusion
Comparison of measurement 2&3
TRF No. EEC_Protocol performance test A
Made with FlippingBook - Online magazine maker