HEAzs Katalog ENG Gesamt

1) HEAzs – Plug ’n’ Play – On / Off

HEAzs is always delivered with a power plug and an approx. two meter long cable. HEAzs is fully functional immediately after plugging it in (plug ’n’ play) - there are no more Installation measures required. The toggle switch on the side is also equipped with a signal lamp.

Simply plug in HEAzs - switch on - enjoy the warmth.

BASIC VERSION EQUIPMENT

2) HEAzs - Plug ‚n‘ Play - On / Off + additional option „time relay“

The HEAzs basic version 1) can optionally be equipped with the additional option “time relay”. The timer function of the integrated time relay has a factory setting of 40 minutes on. This means that the operator can only switch the HEAzs panel on and off or optionally to activate a heating phase of 40 minutes by activating the time relay. After 40 min. the panel switches off automatically. The 40-minute presetting of the time relay can be set manually from 10 min. to 24 hours to be changed.

TS10 - thermostat socket (optional)

TS10 is a digital, temperature-dependent socket outlet for the automatic regulation of electrical heating systems (direct heating, towel dryers) in single-family houses, apartments and offices. TS10 offers numerous possibilities in terms of energy savings and ease of use of electrical heating systems.

Features TS10: • Individually adjustable daily programs • Possibility of setting two temperature levels (comfort, eco) • Simple operation and programming • Short-term changes to the program temperature are possible • Function of permanent switch-off of the consumer (OFF) • Temperature regulation in 0.5 °C steps

• Overview display • Backup battery

Technical parameters Power supply

230, 0 V / 50 Hz

Measurement accuracy

1°C

Hysteresis

Fixed (0,5°C)

Switching element relay

Relais

Temperature changes per day

4

Output

16 A

Backup battery

Yes (NiMh 2,4 V, > 50 hours)

Min. programming time

30 min

Protection class

IP20

Adjustable temperature range

3 °C to 40 °C

Working temperature

0 °C to 40 °C

Temperature setting

0,5 °C

Minimum ad

0,1 °C

HEAzs | 41