2018 Crest Healthcare Catalog

Security &Maintenance

| Mag Lock & Door Holders

Nurse Call 4 - 84

114706 (back)

TVs & Accessories 85 - 104

114706 (front)

Magnetic Door Lock This delayed egress magnetic door lock can be used on perimeter exit doors and internal fire doors to block unauthorized exit and entry while providing a safe means of escape during a fire or other emergency. When someone attempts to exit through a protected door, an alarm will sound to alert staff before the door unlocks. The “nuisance cycle” requires constant pressure on the door between 0-3 seconds to activate the “egress cycle.” Once the “egress cycle” is activated, the door remains locked for 15-30 seconds, giving staff time to respond to the unauthorized exit or, if during a fire or other emergency, unlocks to allow life saving egress.

Fall Management 105 - 118

S P E C I F I C A T I O N S Lock Body:

10 1 ⁄ 2

"W x 2 3 ⁄ 8

"H x 1 5 ⁄ 8

"D

• NFPA Life Safety Code 101 Compliant • Deters unauthorized exit/entry

Mobility & Transfer 119 - 152

Armature:

7 1 ⁄ 4

"W x 2 3 ⁄ 8

"H

x 5 ⁄ 8

"D

Finish:

Anodized brushed aluminum

• Door status indicator • Includes power supply • Can be used as a stand alone system or in conjunction with wandering detection systems

Door Status Output: Form “A” Contact, 500 mA@ 24 VDC Current: 525 mA @ 12 VDC 275 mA @ 24 VDC

Part No. 114706

Description

Price

Power:

12 or 24 VDC

750.95

Magnetic Door Lock, 0-3 second nuisance, 15/30 second egress

Holding Force:

1200 lbs

153 - 192

(field selectable), 12 or 24 VDC

Beds & Room Supply

Assistive Devices 193 - 208

Electromagnetic Door Holders Ruggedly constructed and attractively designed two-part assembly with brushed zinc housing. Perfect for use with stairwell doors, room doors, exit doors or wherever instant closing of a door is necessary for safety or convenience. Can be configured to close any number of doors at the same time (additional hardware is required). Can be operated in conjunction with automatic fire alarm or sprinkler system, or with manual control. Wall units are available in flush or surface mounted versions. Swivel contact plate adjusts to any door angle using a nylon shock absorbing swivel ball.

1508-AQN5

Clinical Care 209 - 230

1505-AQN5

• Silent operation • Mounting hardware is included • Brushed zinc finish on housing • 120 VAC & 24 VAC/DC

LBHOLDING FORCE 25

Carts & Storage 231 - 239

Part No.

Description

Total

Plate

Price

1509-AQN5

Projection

Dimensions

107.95 107.95 109.95 106.95 130.95

1 7 ⁄ 8

2 3 ⁄ 4

"W x 4 5 ⁄ 8 "W x 4 5 ⁄ 8 "W x 4 5 ⁄ 8

"H x 7 ⁄ 32

1509-AQN5 1508-AQN5 1505-AQN5

Door Holder, wall mount, flush mounted Door Holder, wall mount, surface mounted Door Holder, wall mount, flush mounted,

"

"D

4 1 ⁄ 16 2 9 ⁄ 16

2 3 ⁄ 4

"H x 2 7 ⁄ 16 "H x 13 ⁄ 16

" "

"D

2 3 ⁄ 4

"D

short catch plate

1504-AQN5

6 1 ⁄ 8 6 1 ⁄ 8

2 3 ⁄ 4

"W x 4 5 ⁄ 8

"H x 13 ⁄ 16 "H x 3 1 ⁄ 4

1504-AQN5 1501-AQN5

Wall Mount, flush mounted, long catch plate

" "

"D

240 - 269

4 13 ⁄ 16

"W x 4 1 ⁄ 2

Floor Mount, single door

"D

Parts For Electromagnetic Door Holders

Security &Maintenance

1501-AQN5

Part No.

Description

Price

38.65

CS2595-5

Catch Plate Kit for 1501, 1502, 1505, 1508 and 1509 series, includes catch plate assembly, back plate and screws Catch Plate Kit for 1504 series, includes catch plate

Repairs & Services 270 - 272

45.95

CS2598-5

assembly, back plate and screws

CS2598-5

CS2595-5

242

phone: 1-800-328-8908 | fax: 1-800-369-9207 | 2018 | R20

Made with FlippingBook HTML5