Product Catalog
IEC Metric Motors DC Metric Motors LowVoltage Commercial Duty Metric (IEC) Frame Motors
Motors
Pump
Washguard
Features: • Specially designed low voltage DC for use in OEM applications • Combination of features and low cost make these ideal for many uses • IP44(TENV) enclosure
Motors
• Dedicated B14 face mount • Rated S1 for continuous duty 12, 24 & 90 Volt - TENV - B14 Mount
Agricultural Duty Motors
Full Load RPM
App. Wgt. (lbs)
F.L. Amps DC
IEC Frame Catalog Number
List Price Model Number
DC Voltage
Y Notes
HP
Stock
1/15 3000 1/15 3000 1/15 3000
56 56 56 56 56 56 56 56 56
√ 198 980.159 √ 198 980.143 √ 189 980.549 √ 228 970.600 √ 228 970.601 √ 228 970.576 √ 247 970.620 √ 247 970.621 √ 235 970.577
2.3 2.3 2.3 3.0 3.0 3.0 3.5 3.5 3.5
12 24 90 12 24 90 12 24 90
6.4 S, US 3.2 S, US 0.8 S, US 12.0 S, US 5.3 S, US 1.2 S, US 13.1 S, US 6.8 S, US 1.6 S, US
980.159 980.143 980.549 970.600 970.601 970.576 970.620 970.621 970.577
HVAC / Fan
Motors
1/8 1/8 1/8 1/6 1/6 1/6
3000 3000 3000 3000 3000 3000
Special Voltage
Motors
Y Note listing on inside back flap Specifications are subject to change without notice
Once you get to know the LEESON ® IEC motor product line you’ll find a world of applications waiting for these solutions. To know the product is one thing—understanding the technical relationships with NEMA ® motors is another. We are confident that the formulas below will help you when specifying a LEESON Passport Series IEC motor. The formulas for success.
Definite Purpose Motors Brake Motors IEC Motors DC Motors
HORSEPOWER AND KILOWATTS
Example: HP to kW Motor: 25HP NEMA (25 * 0.746) = 18.7kW
HP kW: HP * 0.746 = kW kW HP: kW * 1.3410 = HP
Example: Full LoadTorque Motor: 50HP, 1800 RPM (50 * 5252) / 1800 = 145.9 ft-lbs
FULL LOADTORQUE AND HORSEPOWER
Full LoadTorque: FLTRQ = (HP * 5252) / RPM Horsepower: HP = (TRQ * FL RPM) / 5252
Example: Ft-Lbs to Nm Motor: 10HP, 1800 RPM = 30 ft-lbs 30 * 1.36 = 40.8 Nm
NEWTON METERS AND FOOT POUNDS
Newton Meters: Nm = √3 * ft-lbs Foot Pounds: LB-FT = 1.36 * Nm NOTE:Torque units = ft-lbs LRA: LRA = (KVA/HP * 1000 * HP) / (V * √3)
Example: 3-Phase FLA Motor: 93kW (125HP), 95.4% Efficiency, 86.0% PF (746 * 125) / (460 * .954 * .86 * 1.73205) = 143 Example: LRA Motor: 93kW (125HP), NEMA Code G, 460V (6.29 * 1000 * 125) / (460 * 1.73205) = 987 Amps Example: KVA/HP Motor: 93kW (125HP), NEMA Code G, 460V (1.73205 * 460 * 987) / (1000 * 125) = 6.29
KVA/HP AND LOCKED ROTOR AMPS (STARTING AMPS)
KVA/HP: KVA/HP = (√3 * V * LRA) / (1000 * HP)
KILOVOLT-AMPS AND 3-PHASE FULL LOAD AMPS
KVA: KVA = √3 * V * FLA / 1000 3-Phase FLA: FLA = (746 * HP) / (Volts * Eff. * PF * √3)
303
Made with FlippingBook flipbook maker