NEMA FULL VOLTAGE POWER DEVICES, CONTROL SECTION 1
1-56
— Enclosed combination magnetic starters CR487 non-reversing, instantaneous trip circuit breaker
Ordering code configuration Valid for NEMA sizes 0–4
Digits:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
C R
Steps:
Step 1
Step 2
Step 3
Step 4 Step 5 Step 6 Step 7 Step 8 Step 9
To configure the ordering code, use the tables below to fill in the digit boxes with the appropriate code.
— Step 4 (digit 12) select overload relay Overload relay Thermal bi-metallic ambient compensated (1 NC) Thermal bi-metallic ambient compensated (1 NO–1 NC)
Code
3 4
Solid state overload (1 NO–1 NC)
(#)
(#) Select code for solid state overload amp rating from standard or optional ranges table.
— Solid state overload relay — standard range
— Optional ranges
NEMA size 2 3 and 4
200–208 V
230–240 V
460–480 V
575–600 V
OL amp range
0 and 1
Max. hp
Max. hp
Max. hp
Max. hp
NEMA size OL range
Code
Code
Code
Code
0.4–0.85 0.8–1.7 1.6–3.4 3.2–6.8 6.5–13.5 13–27 25–50 17–35 35–70 65–135
C D E F G H
– – – –
– – – – – – –
3 ⁄
D E
1 2 5
D E
0
0.8 - 1.7 1.6 - 3.4 3.2 - 6.8 6.5 - 13.5 6.5 - 13.5 13 - 27 13 - 27 25 - 50 17 - 35 35 - 70 65 - 135 65 - 135
–
–
–
–
4
1 ⁄
E F G
3 ⁄
E F G
2 3 5
2
4
1 3
2 3
F
F –
G H
G G H H
–
7 1 ⁄
10
G
1
–
–
–
–
2
– – – –
J – – –
7 1 ⁄
H
7
1 ⁄
H
10 20 25
–
–
2
2
K L
2
–
– J – L
–
– J – L
25
H
10
15
J – L –
–
–
M
3
–
–
–
30 50
K L
20 25 40
25 30 50
50
M M
M M
–
–
–
4
100
M
100
M
— Step 5 (digit 13) select auxiliary contacts Auxiliary contacts
— Step 6 (digit 14) select monitoring options Device Phase failure relay with undervoltage protection (panel mounted) — 190-480V (PFR with UV) Phase failure relay with undervoltage protection (panel mounted) — 575V (PFR with UV) None
Code
Code
None 1 NO 1 NC
A B C D E F G H
A
C 2
D 2
1 NO–1 NC
2 NO 2 NC
Phase failure relay — 208 V (PFR) Phase failure relay — 240 V (PFR) Phase failure relay — 480 V (PFR) Phase failure relay — 575 V (PFR)
E 4,6 F 4,6 G 4,6 H 4,6 1 2,5
2 NO–1 NC 1 NO–2 NC
3 NO 3 NC 4 NO 4 NC
J
Elapsed time meter (120 V/60 Hz) wired across coil (ETM)
K
ETM + PFR with UV (190–480 V) ETM + PFR with UV (575 V)
L 2,5,6 N 2,5,6 P 2,4,5,6 Q 2,4,5,6 R 2,4,5,6
L 3
M 3 N 3
ETM + PFR (208 V) ETM + PFR (240 V) ETM + PFR (480 V) ETM + PFR (575 V)
2 NO–2 NC 3 NO–1 NC 1 NO–3 NC
P 3 R 3
S 2,4,5,6 2 Requires oversized enclosure for NEMA sizes 0–2. Select proper NEMA size and enclosure type from step 1 (digits 1–7). 4 Available for type 1 enclosure only. 5 Requires 120 V control circuit voltage or CPT with 120 V secondary. 6 Requires oversized enclosure for phase failure relay.
3 Exceeds maximum number of contacts for some pilot light selections. See step 8 (digit 16).