Control_Flippingbook_NOV 2024

NEMA FULL VOLTAGE POWER DEVICES, CONTROL SECTION 1

1-57

— Enclosed combination magnetic starters CR487 non-reversing, instantaneous trip circuit breaker

Ordering code configuration Valid for NEMA sizes 0–4

Digits:

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

C R

Steps:

Step 1

Step 2

Step 3

Step 4 Step 5 Step 6 Step 7 Step 8 Step 9

To configure the ordering code, use the tables below to fill in the digit boxes with the appropriate code.

— Step 7 (digit 15) select pushbutton/selector switch Pushbutton/selector switch — heavy duty

— Step 8 (digit 16) select pilot device Pilot light (heavy duty) type

Code

Color — functionality Code

None

A

None

A 1 2

Start/stop pushbutton

J

LED lights

Red–across coil Green–across coil

Hand-off-auto (HOA) selector switch

L

Off-on selector switch

M

HOA selector switch and start pushbutton Keyed HOA selector switch, key removal center pos.

S

Red–thru NO aux contact Green–thru NC aux contact

3 7 4 7 5 8 6 7 7 7

N

Red–thru NO aux contact and green–thru NC aux contact

Red–across coil and green–thru NC aux contact

Red–across coil and green–thru NC aux contact and unwired amber

Push-to-test lights

Red–across coil Green–across coil

R S

Red–thru NO aux contact Green–thru NC aux contact

C 7 D 7 E 8 V 7 Y 7

Red–thru NO aux contact and green–thru NC aux contact

Red–across coil and green–thru NC aux contact

Red–across coil and green–thru NC aux contact and unwired amber

7 Maximum of 3 aux contacts may be added to sizes 0 and 1. 8 Maximum of 2 aux contacts may be added to sizes 0 and 1. Maximum of 3 aux contacts may be added to sizes 2–4. Note: Auxiliary contacts wired as part of pilot light selection are in addition to the auxiliary contacts selected from step 5 (digit 13), which are for customer/field connections.

— Step 9 (digit 17) select control options Device

Code

None

A

1 relay, 2 NO-2 NC, 24/120 V coil — unwired

B 2,9 C 2,9

2 relays, 24/120 V coil — unwired

DIN rail — for customer use

D 2 E 2

12 point terminal strip — unwired (12 PT strip)

Space heater with NC contact

H 2,10 J 2,9 K 2,9 L 2,10

1 relay + 12 PT strip 2 relays + 12 PT strip

DIN rail + 12 PT strip + space heater 2 relays + 12 PT strip + space heater

M 2,9,10

Time delay on relay, 24/120 V coil — unwired (TD) Time delay off relay, 24/120 V coil — unwired (TD)

N 2,9 P 2,9 R 2,9 S 2,9

12 PT strip + TD on 12 PT strip + TD off

12 PT strip + space heater + TD on 12 PT strip + space heater + TD off

T 2,9,10 U 2,9,10

2 Requires oversized enclosure for NEMA sizes 0–2. Select proper NEMA size and enclosure type from step 1 (digits 1–7). 9 Relay/timer coil voltage is equivalent to CPT secondary voltage. Requires minimum 100 extra VA CPT option. 10 Maximum number of auxiliary contacts shall be reduced by 1.

General note: If selecting factory installed and wired operator devices (pushbuttons, selector switches and/or pilot lights), control circuit fusing, a control power transformer or 24 V/120 V separate sourced control is required, regardless of protective device rating.

Made with FlippingBook - Online Brochure Maker