Chromalox Big Red Book
Components
Chromalox ® Specification Data Sheet Mica Band and Nozzle Heaters Form PM301 Customer Name: Reference No.:
Date:
Gap
0°
360°
A
270°
90°
I.D.
CL
Width
180°
Note — Drawing Is For Illustration Purposes Only
Operating Conditions 1. APPLICATION (Describe in Detail) :
6. LEAD TYPES: Gap:
o Fiberglas ® (L) o Fiberglas ® (K) o Fiberglas ® (Y) o Conduit (M)
o Metal Braid (A)
Opposing Gap:
Single Center Exit: o Metal Braid (C)
Galvanized
S.Stl.
o 3-PH w/Metal Braid o 3-PH w/Conduit
Galvanized
S.Stl.
o Ground Wire
Single Edge Exit:
o Metal Braid (B)
Other:
o Europlug (EP)
Horiz.
Vert.
90°Box 3-Prong
o Quick Disconnect (QD)
2-Prong
7. OPTIONS:
o Gas o Solid
2. HEATED MEDIUM (Specify) :
o Stainless Steel Sheath o Special Gap Width
o End Fold
o Liquid
(in.)
°F
3. MAXIMUM WORK TEMPERATURE:
o Terminal Box o Holes Location
2-Term.
3-Term. dia. (in.)
4. MAXIMUM WATT DENSITY ALLOWED: Heater Specifications (Check All That Apply) 1. HEATER DIMENSIONS: I.D. (in.) Width (in.) I.D. (mm) Width (mm) 2. RATING: Volts Watts 3. CONSTRUCTION: o One Piece o Two Piece
° from gap
o Notches (attach drawing) 8. THERMOCOUPLE: o Internal Thermocouple
o Right Angle Elbow
Type “J”
Type “K”
o Thermocouple Bayonet Adapter 9. ACCESSORIES: o Ceramic Cover 10. ELECTRICAL REQUIREMENTS: o Chromalox Standards o Insulation Resistance to be Min.
o Cust. Stamped P/N
o Partial
o Expandable
o Hinged Half
o Reversible
meg.
4. CLAMPING:
o Leakage Current to be Max.
mA.
o Separate Strap o Clamping Flanges
o Low Profile Strap o Clamping Pads
o Built-in
o Other (Specify) 11. AGENCY APPROVALS: o None
o Wedgelok
5. POST TERMINATIONS: Type:
o UL Component Recognized
o Standard (T1) o DV or 3-Terminal
o Tandem (T2)
o Parallel (T3)
o CSA Certified o Other (Specify) 12. OTHER SPECIAL FEATURES: (attach detailed information)
Style:
o Standard
o Button
A-152
Made with FlippingBook - Online catalogs