Special Features
Smart Canopy-STC-MSC Gable Lead-Height Change
* FIELD CUT BOTTOM OF WALL PANELS AT ROOF SLOPE HOLD PANELS 1/8" ABOVE HEIGHT CHANGE TRIM.
1/4-14 X 1 1/4" (CS - 6" C.C.) (AP - 12" C.C.) *WALL PANEL
** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.
INSIDE CLOSURE
SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING) (SEE INSET DETAIL) TRI-BEAD TAPE SEALER SPECIAL TRIM TOP (SPT- )
HEIGHT CHANGE ANGLE (A-20-H)
1/4-14 X 1 1/4" WT (12" C.C.) PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
STC/MSC ROOF PANEL
2 7 8 "
PURLIN
(2) #12-14 X 1 1/4" (GA) (36" C.C.)
#12-14 X 1 1/4" (CS - 6" C.C.) (AP - 12" C.C.)
HEIGHT CHANGE TRIM BOTTOM (GHMBF)
RAKE SUPPORT (A-20-S)
RAKE ANGLE (A-20-B)
1 4 "
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
INSIDE CLOSURE WALL PANEL
(2) 1/2" X 1 1/4" BOLTS
** 1/4-14 X 1 1/4" SHOULDER (24" C.C.) OUTSIDE CLOSURE
CANOPY TRUSS FRAMING SPECIAL TRIM (SPT- ) 1/4-14 X 7/8" (12" C.C.)
8"
CL
SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM (SPT- ) TOP (BEFORE ASSEMBLING)
Made with FlippingBook flipbook maker