AOAC-RI ERP Micro June 2016

OMAMAN-29 A/ Collaboartive Study Manuscript OMA ERP June 2016 ERP Use Only

AOAC Official Method 2016.xxx

1 2 3

Listeria speciesin SelectFoods and Environmental Surfaces 3M ™ Molecular Detection Assay(MDA) 2- Listeria Method

First Action 2016 4 5 (Applicable to detection of Listeria speciesin hot dogs (25g & 125g), salmon (25g), deli turkey 6 (25g & 125g), cottage cheese (25g), vanilla ice cream (25g), queso fresco (25g), spinach (25g), 7 melon (whole), raw chicken leg pieces (25g), raw chicken fillet (25g); concrete (3M™ Hydrated 8 Sponge Stick with D/E, 225 mL & 100 mL), stainless steel (3M™ Hydrated Sponge Stick with 9 D/E, 225 mL), and plastic (3M™ Enviroswab with Letheen, 10 mL) environmental samples. 10 11 See Tables 2016.1A and 2016.1B for a summary of results of the inter-laboratory study. 12 See Tables 2016.2A and 2016.2B for detailed results of the inter-laboratory study 15 16 The 3M ™ Molecular Detection Assay (MDA) 2 - Listeria method is used with the 3M ™ 17 Molecular Detection System (MDS) for the rapid and specific detection of Listeria in enriched 18 food and food process environmental samples. The 3M MDA2 - Listeria uses loop-mediated 19 isothermal amplification of unique DNA target sequences with high specificity and sensitivity, 20 combined with bioluminescence to detect the amplification. Presumptive positive results are 21 reported in real-time while negative results are displayed after the assay is completed. Samples 22 arepre-enriched in Demi Fraser broth with ferric ammonium citrate (FAC). 13 14 A. Principle

23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49

B. Apparatus and Reagents

Items (b)-(g) are available as the 3M ™ Molecular Detection Assay (MDA) 2 - Listeria kit

from 3M Food Safety (St. Paul, MN 55144-1000, USA).

(a) 3M Molecular Detection System (MDS100) – Available from 3M Food Safety (St.

Paul, MN 55144-1000, USA).

(b) 3M Molecular Detection Assay 2 – Listeria reagent tubes- 12 strips of 8 tubes. Available from 3M Food Safety (St. Paul, MN 55144-1000, USA).

(c) Lysis Solution (LS) tubes – 12 strips of 8 tubes.

(d) Extra caps – 12 strips of 8 caps (e) Reagent Control – 8 reagent tubes

(f) Quick Start Guide (St. Paul, MN 55144-1000, USA). AOAC Research Institute Expert Review Panel Use Only (h) 3M ™ Molecular Detection Chill Block Insert - Available from 3M ™ Food Safety (St. Paul, MN 55144-1000, USA). (i) 3M ™ Molecular Detection Heat Block Insert - Available from 3M Food Safety (g) 3M ™ Molecular Detection Speed Loader Tray - Available from 3M Food Safety

(St. Paul, MN 55144-1000, USA).

(j) 3M ™ Molecular Detection Cap/Decap Tool for Reagent tubes - Available from 3M

Food Safety (St. Paul, MN 55144-1000, USA).

(k) 3M ™ Molecular Detection Cap/Decap Tool for Lysis tubes – Available from 3M

Food Safety (St. Paul, MN 55144-1000, USA).

(l) Empty Lysis Tube Rack - Available from 3M Food Safety (St. Paul, MN 55144-1000,

USA).

(m) Empty Reagent Tube Rack - Available from 3M Food Safety (St. Paul, MN 55144-

1000, USA).

5

Made with