EPDMMaster Flash
®
EngineeringSpecifications
ASTM D2000 M3 BA510 A14 B13 C12 F17 Z1 Z2 Z3 Z4 Z5 Z6 Z7
GRADE 3
TYPE B
GENERAL TEST TEMP 100C
CLASS A
VOLUME SWELL NO REQ
5
50 DUROMETER (RANGE)
10
TENSILE 10 MPa (APPROX 1450 PSI)
A14
HEAT AGING 70 hrs @ 100C
B13
COMPRESSION SET 22 hrs @ 70C
MAX 25% ASTM D395B
C12
OZONE RESISTANCE
70 hrs @ 50pphm ASTM D1171
100% QUALITY RETENTION
F17
LOW TEMPERATURE BRITTLENESS
3 min @ -40C PASS ASTM D2137 A, 9.3.2
Z1
55 DUROMETER (SPECIFIC TARGET)
Z2
EPDM (SPECIFIC ELASTOMER)
Z3
HORIZONTAL FLAME RESISTANCE, UL 94
NOT TO EXCEED 3” / min
Z4
OZONE RESISTANCE ADVANCED REQUIREMENT
70 hrs @ 500 pphm @ 100F
Z5
ACCELERATED WEATHERING RESISTANCE
(U.V. LIGHT), ASTM G-53
Z6
TEAR RESISTANCE, ASTM D-624, DIE “C”
Z7
RESISTANCE TO DISCOLORATION,
ASTM D-1148 (GREY ONLY)
SILICONE Master Flash
®
EngineeringSpecifications
ASTM D2000 M4 GE 505 A19 B37 C12 F19 G11 Z1 Z2 Z3 Z4
GRADE 4
TYPE G
GENERAL TEST TEMP 225C
CLASS E
VOLUME SWELL MAX 80%
5
50 DUROMETER (RANGE)
05
TENSILE 5 MPa (MINIMUM 725 PSI)
A19
HEAT AGING 70 hrs @ 225C
CHANGE IN HARDNESS MAX + 10 pts
CHANGE IN TENSILE MAX -30%
CHANGE IN ULTIMATE ELONGATION MAX -30%
B37
COMPRESSION SET 22 hrs @ 175C
MAX 50% ASTM D395B
C12
OZONE RESISTANCE
70 hrs @ 50pphm PASS ASTM D1171
F19
LOW TEMPERATURE BRITTLENESS
3 min @ -40C PASS ASTM D2137 A, 9. 3. 2
G11
TEAR RESISTANCE, ASTM D-624, DIE “B”
Z1
55 DUROMETER (SPECIFIC TARGET)
Z2
SILICONE (SPECIFIC ELASTOMER)
Z3
HORIZONTAL FLAME RESISTANCE, UL 94
NOT TO EXCEED 3” / min
Z4
OZONE RESISTANCE ADVANCED REQUIREMENT
70 hrs @ 500 pphm @ 100F
The “Z” Parameters are proprietary standards adopted by Aztec Washer to more clearly indicate the type of material and its
superior performance characteristics as related to the typical pipe flashing environment.
NOTE: the additional of “Z3” to assure compliance with international building codes and “Z4” which clearly exceeds the
performance required by the industry standard, “C12”.
The Master Flash pipe flashing enjoys the only listing granted to date by the International Association of Plumbing and
Mechanical Officials and carries the U.P.C. (Uniform Plumbing Code) seal.
As part of a standard classification system for rubber products these general specifications
present conservative engineering minimums which should be used for design criteria.
General Recommendations
Must be tested for extreme applications
YEAR
WARRANTY
35