EPDMMaster Flash

®

EngineeringSpecifications

ASTM D2000 M3 BA510 A14 B13 C12 F17 Z1 Z2 Z3 Z4 Z5 Z6 Z7

GRADE 3

TYPE B

GENERAL TEST TEMP 100C

CLASS A

VOLUME SWELL NO REQ

5

50 DUROMETER (RANGE)

10

TENSILE 10 MPa (APPROX 1450 PSI)

A14

HEAT AGING 70 hrs @ 100C

B13

COMPRESSION SET 22 hrs @ 70C

MAX 25% ASTM D395B

C12

OZONE RESISTANCE

70 hrs @ 50pphm ASTM D1171

100% QUALITY RETENTION

F17

LOW TEMPERATURE BRITTLENESS

3 min @ -40C PASS ASTM D2137 A, 9.3.2

Z1

55 DUROMETER (SPECIFIC TARGET)

Z2

EPDM (SPECIFIC ELASTOMER)

Z3

HORIZONTAL FLAME RESISTANCE, UL 94

NOT TO EXCEED 3” / min

Z4

OZONE RESISTANCE ADVANCED REQUIREMENT

70 hrs @ 500 pphm @ 100F

Z5

ACCELERATED WEATHERING RESISTANCE

(U.V. LIGHT), ASTM G-53

Z6

TEAR RESISTANCE, ASTM D-624, DIE “C”

Z7

RESISTANCE TO DISCOLORATION,

ASTM D-1148 (GREY ONLY)

SILICONE Master Flash

®

EngineeringSpecifications

ASTM D2000 M4 GE 505 A19 B37 C12 F19 G11 Z1 Z2 Z3 Z4

GRADE 4

TYPE G

GENERAL TEST TEMP 225C

CLASS E

VOLUME SWELL MAX 80%

5

50 DUROMETER (RANGE)

05

TENSILE 5 MPa (MINIMUM 725 PSI)

A19

HEAT AGING 70 hrs @ 225C

CHANGE IN HARDNESS MAX + 10 pts

CHANGE IN TENSILE MAX -30%

CHANGE IN ULTIMATE ELONGATION MAX -30%

B37

COMPRESSION SET 22 hrs @ 175C

MAX 50% ASTM D395B

C12

OZONE RESISTANCE

70 hrs @ 50pphm PASS ASTM D1171

F19

LOW TEMPERATURE BRITTLENESS

3 min @ -40C PASS ASTM D2137 A, 9. 3. 2

G11

TEAR RESISTANCE, ASTM D-624, DIE “B”

Z1

55 DUROMETER (SPECIFIC TARGET)

Z2

SILICONE (SPECIFIC ELASTOMER)

Z3

HORIZONTAL FLAME RESISTANCE, UL 94

NOT TO EXCEED 3” / min

Z4

OZONE RESISTANCE ADVANCED REQUIREMENT

70 hrs @ 500 pphm @ 100F

The “Z” Parameters are proprietary standards adopted by Aztec Washer to more clearly indicate the type of material and its

superior performance characteristics as related to the typical pipe flashing environment.

NOTE: the additional of “Z3” to assure compliance with international building codes and “Z4” which clearly exceeds the

performance required by the industry standard, “C12”.

The Master Flash pipe flashing enjoys the only listing granted to date by the International Association of Plumbing and

Mechanical Officials and carries the U.P.C. (Uniform Plumbing Code) seal.

As part of a standard classification system for rubber products these general specifications

present conservative engineering minimums which should be used for design criteria.

General Recommendations

Must be tested for extreme applications

YEAR