Step

Press Button(s)

COMMENTS

Press or to select:

Displayed

(Factory Default)

HOLD

(0:00)

0 to 8 hrs (in

15 minute increments)

2

(FA)

SL

Select temporary Hold time

N/A

N/A

E

(ON)

OFF

4

5

LOC

(OFF)

ON

0 HI

(0)

4 LO

to

4 HI

°(F)

°C

Returns to normal operation

Returns to normal operation

6

7

Select Energy Management Recovery

OFF

or

ON

Select Compressor lockout

OFF

or

ON

Select temperature display adjustment higher or lower

Select temperature display to

°F

or

°C

RUN

PRGM

and

RUN

*

*

3

d-L

(ON)

OFF

Select display backlight

OFF

or

ON

*

*

Filter

(000)

0 to 1950 hours

(in 50 hour increments)

Select filter replacement run time

*

*

*

Select

FA

or

SL

(Fast or Slow) heating cycle rate

Configuration Menu

N/A

Step Step

2 2

N/A

4

5

6

7

8

3 3

1

1

Step

2

4

4

5

5

6

6

7

7

8

8

9

9

3

1

1

SYSTEM switch must be OFF to configure thermostat

options

Set

SYSTEM

switch to

OFF

Set

SYSTEM

switch to

HEAT

or

COOL

1

N/A N/A

N/A N/A

N/A N/A

Step

2

4

N/A

5

6

7

8

3

1F80-241

1F80-361

1F86-241

1F86-344

1F87-361

N/A

1

N/A

*9

Step

2

4

5

N/A

6

7

8

3

*1F80-240

1

N/A

8

Step

2

N/A

N/A

4

5

6

7

3

1F80-224

* 1F80/1F87 - Press

HOLD

to advance to next item or

TIME

to move backwards to previous item

1F86 - Press and

to advance to next item

1F80-240 is HEAT only

RH

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Heat only, 3-wire, single transformer systems

TRANSFORMER

Heating

System

Fan

Relay

Y

C ‡

RC

JUMPER

WIRE

O B

For 1F80-361 and

1F86-344 2-wire

Heat only, attach

to RH and W.

NOTE

RH

Y

24 VAC

120 VAC

Hot

Neutral

TRANSFORMER

THERMOSTAT

SYSTEM

G W

Cool only, 3-wire, single transformer systems

Cooling

System

Fan

Relay

RC

O B C ‡

JUMPER

WIRE

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Heat/cool, 4-wire, single transformer systems

TRANSFORMER

Heating

System

Fan

Relay

Cooling

System

RC

JUMPER

WIRE

O

C ‡ B

RED

jumper wire (provided with thermostat)

must

be

connected between thermostat

RH

and

RC

terminals

for proper thermostat operation with this system.

NOTE

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G

W

Heat/cool, 5-wire, two-transformer systems

HEATING

TRANSFORMER

Heating

System

Fan

Relay

Cooling

System

RC

24 VAC

120 VAC

Hot

Neutral

COOLING TRANSFORMER

O B C ‡

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G W

Heat pump with reversing valve energized in COOL

TRANSFORMER

Reversing

Valve*

RC

O B C ‡

JUMPER

WIRE

Compressor

Contactor

JUMPER

WIRE

* Reversing valve is energized when the

system switch is in the COOL position

Fan

Relay

RH

Y

24 VAC

120 VAC

Hot

Neutral

THERMOSTAT

SYSTEM

G W

Heat pump with reversing valve energized in HEAT

TRANSFORMER

Reversing

Valve*

RC

O B C ‡

JUMPER

WIRE

Compressor

Contactor

JUMPER

WIRE

* Reversing valve is energized when the

system switch is in the HEAT position

Fan

Relay

The following table allows you to customize the options on your Comfort-Set thermostat.

1F80-224 / 1F80-240 / 1F80-241 / 1F80-361

1F86-241 / 1F86-344 / 1F87-361

CONFIGURATION AND

TYPICAL WIRING DIAGRAMS

CONFIGURATION

TYPICAL WIRING DIAGRAMS

www.white-rodgers.com

159