Parameter

Method Performance

Please

report in units as stated in SMPR!

Weighting

factor for

parameter

Suitability Ranking (1-

3-5)

(select from drop-down

list, 5 = best)

SPIFAN matrices

Applicable to all forms of infant, adult, and/or pediatric

formula (powders, ready-to-feed liquids, and liquid

concentrates).

Any combination of milk, soy, rice, whey, hydrolyzed

protein, starch, and amino acids, with and without intact

protein.

Applicable to all product types.

1

5

All analytes defined in the

applicability statement are

measured.

Chloride

Chloride is measured.

1

5

Spike recovery (%)

95 - 105 %

SPIFAN samples (15) were spiked at 2 levels of

chloride on 3 separate days.

Spike level 1: Average recoveries of 100.1 %

(Recovery Range 101- 103%)

Spike level 2: Average recovery of 100.0 %

(Recovery Range 99 - 103 % ).

2

5

Bias vs SRM NIST 1849a informational value = 710 mg/100g

Value found = 685 mg/100g , 97.2 % recovery.

No bias at 95% confidence level.

See Table 2

3

5

Average RSDr = 0.31% (17 products)

(RSDr Range 0.03 - 1.60 %; Range evaluated 20 -

167 mg/100g RTF)

See table 3 for values

Average RSDr = 0.54% (17 products)

(RSDr Range 0.09 - 2.77 %; Range evaluated 20 -

167 mg/100g RTF)

5

5

5

b

Units

Chloride

< 2 %

< 4 %

Chloride

Limit of quantification (LOQ)

Method Reference #

LI-08.580

Method title:

Principle of the method:

Chloride by Potentiometry

A quantitative method for the determination of the chloride and sodium chloride contents by potentiometric

titration using silver nitrate.

1.4-1060 mg/100g

Notes:

Overall Score

Intermediate Reproducibility

(RSDiR)

5

Recommendation of ERP

2 years after First Action Status

Chloride

Unknown

Not required

5-500 mg/100g*

Chloride

5 mg/100g*

1.4 mg/100g*

See table 3 for values

Evaluation of Method Performance vs. SMPR requirements.

Feedback from Users of the Method since being awarded

First Action

Official Methods

Status

Repeatability (RSDr)

Reproducibility (RSDR)

Accuracy/Recovery

5

5

ADDITIONAL EVALUATION PARAMETERS

SMPR Requirement

Analytical Range.

1

AOAC SMPR: 2014.015

Limit of detection (LOD)

1

a

Concentrations apply to (1) "ready to feed liquids" "as-is"; (2) reconstituted powders (25 g into 200 g water); and (3) liquid concentrates diluted 1:1 by weight.

Did Method Author Consider ERP’s Method Specific

Recommendations

(See web link to specific method

comments):

Decision by ERP

Proprietary equipment

Laboratory safety

Other Considerations

move to Final Action/repeal/remove/expand 2 year term

85

No unique proprietary equipment/accessories are required.

Method does not require any special safety precautions e.g. personal protection from highly toxic solvents.

3

1

2

5

Bias against established method

Analytical equipment

1

Adequate proof of performance via system suitability

Analytical equipment is commonly available in most labs.

SPIFAN ERP Checklist v 1.6

27.06.2013

Chlor-02 MEF Form

FOR ERP USE ONLY