GE Énergie
COMPAGNIE GÉNÉRALE ÉLECTRIQUE
TRANSFORMATEURS À SEC
NOTES :
1) TOUTES LES UNITÉS SONT CERTIFIÉES cUL SELON LES NORMES CSA C9 ET CSA C22.2 N
O
47 ET SATISFONT AUX
EXIGENCES D’EFFICACITÉ DE LA NORME CSA C8022
2) LES TRANSFORMATEURS UTILISENT LA CLASSE D’ISOLATION 220 °C HOMOLOGUÉE UL. LES ÉLÉVATIONS DE
TEMPÉRATURE POUR LES CAPACITÉS EN kVA SPÉCIFIQUES QUI FIGURENT DANS LE TABLEAU CI-DESSOUS SONT ÉTABLIES
LORSQUE LE TRANSFORMATEUR EST MONTÉ DANS UN BÂTI STANDARD.
3) LES TRANSFORMATEURS SONT CONÇUS POUR UN MONTAGE AU SOL. DES SUPPORTS DE MONTAGE MURAL NE SONT PAS
DISPONIBLES EN OPTION POUR LES MODÈLES DE TRANSFORMATEURS QUI FIGURENT DANS LE TABLEAU CI-DESSOUS.
4) LES TRANSFORMATEURS SONT DES MODÈLES À SEC, DE CLASSE AA, AVEC BÂTI VENTILÉ POUR USAGE À L’INTÉRIEUR. DES
DISPOSITIFS DE PROTECTION CONTRE LES INTEMPÉRIES SONT DISPONIBLES POUR CONVERTIR TOUS LES MODÈLES AU
TYPE 3R POUR USAGE À L’EXTÉRIEUR TOUT EN RESPECTANT LA GARANTIE.
5) S’APPLIQUE LORSQUE DES DISPOSITIFS DE PROTECTION CONTRE LES INTEMPÉRIES SONT INSTALLÉS. CES DISPOSITIFS
SONT EXPÉDIÉS SOUS FORME D’ENSEMBLES À INSTALLER SUR LE CHANTIER.
6) L’ENTRÉE DE CÂBLE PEUT ÊTRE PRATIQUÉE UNIQUEMENT SUR LE CÔTÉ GAUCHE, LE CÔTÉ DROIT OU LE DESSOUS
DES PANNEAUX DU BÂTI. L’ENTRÉE DE CÂBLE NE PEUT PAS ÊTRE PRATIQUÉE SUR LE DEVANT, L’ARRIÈRE OU LE
DESSUS DES PANNEAUX.
7) 7) DES TROUS MESURANT 0,58 PO DE DIAMÈTRE SONT FOURNIS POUR LES TERMINAISONS INSTALLÉES PAR LE CLIENT.
8) POUR SOULEVER L’ÉQUIPEMENT AUTREMENT QU’AVEC UN TRANSPALETTE OU UN CHARIOT ÉLÉVATEUR À FOURCHE,
INSÉREZ LES FOURCHES AU COMPLET SOUS LES GRILLES DE LEVAGE AVANT ET ARRIÈRE. POUR SOULEVER L’ÉQUIPEMENT
AVEC UNE GRUE, UTILISEZ LES TROUS DE 1 PO DE DIAMÈTRE DANS LES BRIDES DE FIXATION DU NOYAU.
9) GRIS ANSI 61 EST LE CODE DE COULEUR DE LA PEINTURE.
10) UN DÉGAGEMENT MINIMUM DE 6 PO EST REQUIS POUR TOUS LES MURS.
VALEURS kVA ET ÉLÉVATIONS DE TEMPÉRATURE TYPES
CONDUCTEUR
RÉF. kVA À
POIDS
EN LB
(APPROX.)
NIVEAU dB
ÉLÉV.
150 °C
ÉLÉV.
115 °C
ÉLÉV.
80 °C
ALUMINIUM 225 150 S/O
1590
55
cuivre
225 150 S/O
1700
QTÉ CONDUCTEUR
ENROULEMENT kVA ÉLÉV. DE
TEMP.
TENSION
PRISES
PRIMAIRE
SECONDAIRE
SAUF INDICATIONCONTRAIRE,TOUTESLES
DIMENSIONSSONTEXPRIMÉESENPOUCES (mm).
DESSIN GRAPHIQUE (UNITÉ ENCASTRÉE) TP1, 3 PHASES
RÉV.
COMPAGNIE GÉNÉRALE ÉLECTRIQUE
GE Consommation et Industrie
PROJECTIONDANSLETROISIÈMEDIÈDRE
FEUILLE1DE6
35,5
(901)
38,5
(979)
2,1 TYP
(52) (NOTE 4)
33,0
(838)
5,2
(133)
ENTRÉE
DU CÂBLE
LATÉRAL
(NOTE 6)
17,0
(433)
8,2
(208)
27,0 MTG
(686)
3,0
(76)
45,5
(1154)
35,2 MTG (895)
1,7
(43)
ZONE HT & BT DE LA
TERMINAISON (NOTE 7)
35,2 (895)
REF
FENTE 0,438 X 2,000
PO (4 PLACES)
27,0
(686)
REF
VUE EN SOUS-FACE DE
LA CONFIGURATION DES
TROUS DE MONTAGE
5,2
(132)
ZONED’ENTRÉEDESCÂBLES
ENDESSOUS (NOTE 6)
VUE EN PLAN
VUE DE FACE
VUE LATÉRALE
VUE ISOMÉTRIQUE
1,0
(26)
CLIENT
N
O
DE CATALOGUE
LIGNE
PROJET
DÉSIGNATION
N
O
DESSIN