Background Image
Table of Contents Table of Contents
Previous Page  66 / 236 Next Page
Basic version Information
Show Menu
Previous Page 66 / 236 Next Page
Page Background

KHS GmbH

Juchostraße 20

D-44143 Dortmund

Deutschland

Tel: +49.231.569 0

info@khs.com

* Subject to technical modifications and price changes. On request, we will be glad to provide you with a binding offer.

Version 1 Date 20.03.2014

Description

The multiple-zone, induction heating system of the gluing roller shell distributes

the temperature very exactly using the temperature sensors and control

electronics integrated in the shell. The temperature sensors signal the actual

temperatures via a non-contact data transmitter to the controller that

subsequently adapts the target temperatures as required. The heat generated by

the heater has a significant impact on the aging process of the integrated

electronic components. Thanks to the new encapsulated design, the annular gap

of the transmitter is now safely protected from soiling thereby increasing process

reliability yet again. The newly integrated axial bearing of the rotor in the stator

housing is likewise a guarantee for a disruption-free data transmission and thus

perfectly controlled temperatures for labeling. This reliably rules out the

possibility of any transmitter misadjustment.

Benefit

Protection against sudden complete failure:

The conversion involves moving the electronic components of the temperature

control out of the heat-affected zone. The service life of the relevant components

is thus considerably longer. This additionally lengthens the time between

maintenance intervals. Any required replacement in the future does not

necessitate dismantling the entire assembly. One day less required for each

overhaul.

Scope of supply

Non-contact measured date

transmitter ( YOM 2011 ) IP 65

Temperature sensor PT100

Gluing roller shell base

Belt pulley

Torque reaction bar

Contact

Sven.Lasner@KHS.com

KHS Innoket

360 MEASUREMENT TRANSMISSION

EN

KHS Innoket

TECHNICAL UPGRADE

Suitability

Innoket 360 up to Jan. 2011