SAR

Sodium Absorbtion Ratio (meq/L).

Sensor Check™

Allows users to check electrode status at any

time.

°SH

Soxlet Henkel degrees is determined by

titrating a 50 mL sample with 0.1 M sodium

hydroxide to a phenolphthalein end point.

SHE

Standard Hydrogen Electrode.

SMART electrode

WithmodelsthatfeatureourSMARTcircuitry,

an exclusive microchip embedded inside the

electrode retains the calibration data and

assigns an identity code to the host unit. As

soon as the electrode is connected to a pH

meter in the SMART series, it is recognized

and its characteristics retrieved. The meter

then uses the accessed calibration data

as a reference for future measurements.

Once each SMART electrode is calibrated,

these electrodes can be used in succession

without requiring new calibration. Hanna’s

intelligent electrodes help eliminate errors

and will save time when working with more

than one electrode.

SOP

Standard

Operating

Procedures

means

documented procedures which describe

how to perform tests or activities normally

not specified in detail in study plans or

tests guidelines.

SOUR

Specific Oxygen Uptake Rate. This is used

to determine the oxygen consumption or

respiration rate; SOUR is measured in mg

of oxygen consumed per gram of volatile

suspended solids per hour.

SPDT relay

Single Pole Double Throw relay.

Specificity

Specificity

is

the

ability

to

assess

unequivocally the analyte in the presence

of components which may be expected to

be present. Typically these might include

impurities, degradants, matrix, etc.

Speedsafe™

Each Hanna stirrer is equipped with a speed

sensing device (opto-sensor) coupled with

an FVC (frequency voltage converter), which

monitors the speed. As the speed reaches a

presetmaximum level, the speed limiter shuts

down the VCO to slow down the motor speed.

This ensures that when the load is suddenly

removed from the stirrer, the motor will not

accelerate to such a high speed that will be

hazardous to both the user and the stirrer; a

feature not commonly found in conventional

stirrers.

SPST Relay

Single Pole Single Throw relay.

SRM

Standard ReferenceMaterial (CRMof National

Institute of Standards and Technology).

Storage Solution

Solution used to keep the electrode moist

when not in use.

TDS

Total Dissolved Solids (often abbreviated

TDS) is a measure of the combined content

of all inorganic and organic substances

contained in a liquid in: molecular, ionized or

micro-granular (colloidal sol) suspended form.

TDS Factor

When a solution does not have a similar

ionic content to natural water or salt water,

then a TDS conversion factor is needed to

automatically adjust the readings. TDS = CF

x conductivity (CF is TDS Conversion factor).

TFPC

Thin Film Polymer Capacitance.