Transesophageal ultrasound
Scope
Trachea
Subcarinal
lymph node
Esophagus
Transesophageal ultrasound-guided fine needle aspiration of a subcarinal
lymph node. Sensitivity of 78% and specificity of 71%
www.uniklinikum-dresden.deToloza et al, Chest 2003