Dose calculation – AAPM-TG43

The 1D Approximation

The anisotropy factor φ

an

(r) is thus defined as the ratio of the dose rate

at distance r, averaged with respect to solid angle, to the dose rate on the

transverse y-axis (θ = θ

0

= 90

°

) ) at the same distance.