Pre-plan versus intra-operative plan

Pre-planning

• Outpatient TRUS prior to implant

• Positioning probe as outpatient situation

• Less OR time needed

• No possibility for interactive planning

• Oedema effect not taken into account

• No physicist/dosimetrist needed in OR

• Number of seeds to order more accurate

Intra-operative plan

• TRUS at time of implant

• Probe stays in position during whole treatment

• More OR time needed

• Interactive planning possible

• Geometry changes are taken into account

• Physicist/dosimetrist needed in OR

• Risk of inappropriate seed ordering